Installation Instructions – IFLD Infrastructure Flood
INSTALLATION
Yoke Mounting (Figure 1)
Tools Required:
Ratchet, torque wrench (ft-lbs), 3/4" and
1-1/8" socket, and electrical wiring tools as needed.
1.
Mount luminaire to a surface ensuring maximum
contact across the bottom surface of the yoke as
shown in Figure 1. Use hole pattern provided in Figure
2 to properly align the yoke with center hole and 2x .56
slots with spacing of 3.75 inches.
N
ote:
Do not invert or mount the yoke in any other
orientation besides what is shown in figure 1.
N
ote:
Mounting hardware recommended (supplied by
others); all hardware must have proper outdoor
corrosion-resistant coating (Hot-Dip Galvanized or
equivalent:
a.
(2) 1/2"-13 flange bolts (long enough to go through
the yoke and mounting structure) with (2) 1/2"-13
nuts to be mounted in 3.75 inch center spacing.
Torque to 40 ft lbs after horizontally aiming the
luminaire.
b.
(1) 3/4 bolt with flat washer thru center bolt (long
enough to go through the yoke and mounting
structure) and (1) 3/4 nut. Torque to 80 ft-lbs.
2.
Loosen but do not remove the (2) center bolts (Fig 1).
3.
Rotate luminaire to desired aiming position and tighten
center bolts to 40 ft-lbs.
4.
Refer to wiring diagrams for power connection (Fig 3).
(2) 1/2-13
center bolt
tightening
torque
40 ft lbs
Figure 1.
2
Cooper Lighting Solutions
3/4 center bolt
tightening torque
80 ft lbs
Yoke mount
IB506022EN
Installation instructions
2X Ø.56 2X 1.88
(47 .6)
(14.2)
Figure 2.
Ground
Figure 3.
Slip Fitter Mounting (Figure 4, 5)
N
ote:
The slip fitter is only intended to mount on a vertical
orientation with a suitable 3" diameter pole or
accessory tenon topper. For 2 3/8 tenon sizes,
a separate spacer accessory is needed that isn't
included with the standard unit.
Tools Required:
Ratchet, 9/16˝ socket, Torque wrench
(ft-lbs), 1/4" Allen hex, 3/4 open wrench and #2 Phillips
screwdriver.
1.
Loosen (3) #8 screws to remove the access cover from
the slip fitter arm. Set aside for installation.
2.
Remove the protective plug on the lower side of the
slip fitter arm and discard.
3.
Pull the supply wire leads through the top of pole or
tenon topper. Support fixture and lower onto pole
while feeding supply wires through the slot in the slip
fitter (Fig 5).
4.
Once fixture is oriented properly, hand tighten the (3)
angled set screws to secure fixture in place. Hand
tighten the lower (3) set screws and then torque the
upper angled set screws to 25 ft-lbs. Install (3) hex
nuts to the lower set screws and torque both the (3)
set screws and (3) nuts to 25 ft-lbs (Fig 4)
Ø.88
(22.2)
3.75
(95.3)
Black
White
Fixture
Green