PRE-INSTALLATION CONFIRMATION
Electrical Connection
Verify that the installation meets the following specifications:
Power supply: 220V-240V, 50/60 Hz only
10A fuse.
The electrical connection must be equipped with a device that provides circuit interruption and
protection against earth leakage faults, such as a residual current device (RCD) with a sensitivity of
30 mA.
The product's electrical connection must include:
» An upstream multipole circuit breaker (contact opening at least 3 mm: fuse, circuit breaker).
» Connections using properly secured cables with a minimum cross-sectional area of 3 x 2.5 mm²
in single-phase (phase, neutral, earth). The grounding cable must be green/yellow in color.
Electrical cables must be protected using a corrugated conduit. Ensure that the necessary provisions
are made.
Waterway preinstallation
Reserve pipeline for water supply hose
212
Water Preinstallation Dimensions
After installation
8