IMPACT 1640
7.1
DIGI-TRAC™ CONTROL SYSTEM ERROR
MESSAGES
The following error message screens appear
i
whenever the Digi-Trac™ Control System detects
a problem with the sprayer. Once a problem
occurs and the error message appears, the
sprayer will shut down.
Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce
the risk of an injection injury, injury from moving
parts or electric shock. Always unplug the sprayer
before servicing!
CHECK TRANSDUCER SCREEN
The Check Transducer screen appears
when the transducer has become
disconnected or is defective. Take
the sprayer to a Titan authorized
service center for repair.
CHECK POTENTIOMETER SCREEN
The Check Potentiometer screen
appears when the potentiometer has
become disconnected or is defective.
Take the sprayer to a Titan authorized
service center for repair.
LOW VOLTAGE SCREEN
The Low Voltage screen appears
when the sprayer shuts down
because of low input voltage. Check
the power supply and correct the
problem. Restart the sprayer by
following the "Painting" procedure in
the Operation section of this manual.
HIGH MOTOR TEMPERATURE SCREEN
The High Motor Temperature screen
appears when the temperature of the
motor has risen too high. Take the
sprayer to a Titan authorized service
center for repair.
HIGH MECHANICAL LOAD
The High Mechanical Load screen
appears when the sprayer shuts
down because of high current or
when the sprayer goes into current
fold back mode. Take the sprayer to a
Titan authorized service center for repair.
HIGH CONTROL TEMPERATURE
Indicates the Digi-Trac is shut down
due to excessive heat. Take the
sprayer to a Titan authorized service
center for repair.
CHECK MOTOR
Indicates the motor or motor hall
affect sensors are defective. Take the
sprayer to a Titan authorized service
CHECK TRANSDUCER
center for repair.
BAD HALL CYCLE POWER
Indicates the motor is shut down due
to connection problems between
the motor and controller. Take the
CHECK
sprayer to a Titan authorized service
POTENTIOMETER
center for repair.
LOW VOLTAGE
HIGH MOTOR
TEMPERATURE
TROUBLESHOOTING
HIGH MECHANICAL
LOAD
HIGH CONTROL
TEMPERATURE
CHECK MOTOR
BAD HALL CYCLE
POWER
21