INSTALLATION
STEP
6
Install
the
Door
Control
Locate door control within sight of door, at a
minimum height of 5 feet (1.5 m) where small
children cannot reach, away from moving parts of
door and door hardware. If installing into drywall, drill
5/32" holes and use the anchors provided. For
pre-wired installations (as in new home
construction), it may be mounted to a single gang
box (Figure 2).
1. Strip 7/16" (11 mm) of insulation from one end of
bell wire and connect to the two screw terminals
on back of door control by color: white wire to
2 and white/red wire to the 1.
2. Remove cover by gently prying at slot in top of the
cover with a small flat head screwdriver. Fasten
with 6ABx1-1/4" self-tapping screws (drywall
installation) or 6-32xl"
machine screws (into gang
box) as follows:
• Install bottom screw, allowing 1/8" (3 mm) to
protrude above wall surface.
• Position bottom of door control on screw head
and slide down to secure. Adjust screw
for snug fit.
• Drill and install top screw with care to avoid
cracking plastic housing. Do not overtighten.
• Insert top tabs and snap on cover.
3. (For standard
installation
only) Run bell wire up
wall and across ceiling to motor unit. Use
insulated staples to secure wire in several places.
Do not pierce wire with a staple, creating a short
or open circuit.
4. Strip 7/16" (11 mm) of insulation from end of bell
wire. Connect bell wire to the quick-connect
terminals as follows: white to white and white/red
to red.
NOTE: When connecting multiple door controls to
the opener, twist same color wires together. Insert
wires into quick-connect holes: white to white and
red/white to red.
5. Position the antenna wire as shown.
6. Use tacks or staples to permanently attach
entrapment warning label to wall near door
control, and manual release/safety reverse test
label in a prominent location on inside of
garage door.
NOTE: DO NOT connect power and operate
opener at this time. The trolley will travel to the
full open position but will not return to the close
position until the sensor beam is connected and
properly aligned.
/
Bell
Wire
To prevent possible SERIOUSINJURYor DEATHfrom
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLYto 24 VOLTlow voltage wires.
To prevent possible SERIOUSINJURYor DEATHfrom a
closing garage door:
• Install door control within sight of garage door, out of
reach of children at a minimum height of 5 feet
(1.5 m), and away from all moving parts of door.
• NEVERpermit children to operate or play with door
control push buttons or remote control transmitters.
• Activate door ONLYwhen it can be seen clearly, is
properly adjusted, and there are no obstructions to door
travel.
• ALWAYSkeep garage door in sight until completely
closed. NEVERpermit anyone to cross path of closing
garage door.
Outside
Keylock Accessory Connections
To opener quick-connect
terminals: white to white;
white/red to red.
HARDWARE
SHOWN ACTUAL
SIZE
Control Panel (std installation)
Control Panel (pre-wired)
Insulated
Staples
Drywall Anchors
Figure 1
REMOVE & REPLACE
COVER
To Replace,
Insert Top
Tabs First
Figure 2
PRE-WIRED
INSTALLATION
24 Volt
2-Conductor
Bell Wire in
Gang Box
Quick-Connect
Push Bar
Top
Mounting
Hole
Terminal
> Screws
Bottom
Mounting
Hole
BACK VIEW'
17
Bell Wire
To release wire, push in tab
with screwdriver
tip
Strip wire 7/16"
(11 ram)
®
Door Control
Connections
White
Grey
Antenna