OPERATIONS INSTRUCTION
Preparation
before use
Detail
operation
during use
Place the detector on the mobile cart or under the hood.
Open the filling cap and drain 10ml of test liquid into the filling
port (A).
NOTE
If the test oil is overfilled, please drain some oil out through the
oil drain outlet (I).
After completing the first two steps, start using the SDT205S.
Fit the smoke hose to the smoke outlet (J) and the power cord
to the power socket (K).
Connect the power clip to the DC 12V car battery and the
power indicator lights up.
NOTE
The red clip is connected to the positive terminal (+) and the
black clip is connected to the negative terminal (-). For optimum
performance of the smoke leak detector, the car battery should
be fully charged in advance.
Press the air mode switch (B) and the equipment begins to
produce pressurized air.
Press the smoke mode switch (C) and the unit begins to
produce smoke.
TIP
The smoke output can be observed and controlled through the
smoke flow meter (E) and the smoke flow regulating valve (F).
NOTE
When the internal temperature reaches 75°C, the product will
start self-protection function and stop working automatically.
Press the smoke control switch (C) to stop the smoke output.
It is recommended to drain out the remaining test oil for next
use in case the detector is not used for a long time.