What you need to have before you start
1. Power drill and 1/4'' drill bit.
2. 1/2'' or adjustable wrench.
3. Flatblade and Philips head screwdrivers.
Saddle-type
Shut offvalve
compression
(1/4" outlet)
1/4" extension
tubing
4.You need to purchase several item to
compalet this connection.You may find
these items sold as a kit at local hardware
store.
Connecting to the water supply line
1.
First, shut off the main water supply.
2.
Using a power drill and a 1/4'' drill bit
drill into the cold-water line and
connect the saddle-type shutoff valve.
Cold water line
Pipe clamp
Shut off Valve
one 1/4"
1 ferrule
(sleeve)
1 Coupler
2 Clips
3. Connect 1/4'' extension tubing to shutoff
valve outlet.
Saddle-Type
Shutoff Valve
Packing Nut
Outllet Valve
4.
Flush the tubing. Turn the main water
supply on and flush out the tubing until
the water is clear. Then, shut the water
off at the water valve after about a quart
of water has flushed through the tubing.
5.
Connect the extension tubing line with
the line on the back of the fridge via
the coupler. Fully insert the extension
tubing into the coupler, and then insert
the clip onto the coupler to lockup the
tubing. Do the same with the other
end. After both clips are inserted,
check the line to make sure it is held
firmly by the clip.
Water line
Coupler
Note:
Ensure that the water line does not get
pinched or bent when installing.
This can result in improper water flow
through the line and will affect the
functionality of the fridge.
Compression Nut
1/4" Extension
tubing
Ferrule(sleeve)
Clip
Water line
11