en-us_main.book.book Page 19 Monday, September 11, 2023 4:50 PM
insulation from each wire. Bend the ends of
the three wires into a hook shape.
2
Remove the terminal block access cover on
the upper back of the appliance.
3
Install UL-listed strain relief into the power
cord through-hole.
4
Thread the 3-wire, #10 AWG minimum copper
conductor power cable prepared in step 1
through the strain relief.
a
Terminal block
b
UL-listed strain relief
c
UL-listed 3-wire power cord
5
Attach the two hot leads (black and red) of the
power cord to the outer terminal block
screws.
6
Attach the neutral (white) wire to the center
terminal block screw.
7
Connect the external ground (if required by
local codes) to the green ground screw.
8
Tighten all screws securely.
9
Reinstall the terminal block access cover.
1'' (2.5 cm)
Installing the Dryer Side
Vent Kit
The appliance is configured to vent to the rear. It
can also vent to the side.
• Use long-sleeved gloves and safety glasses.
• Use a heavy metal vent.
• Do not use plastic or thin foil ducts.
• Clean old ducts before installing the appliance.
NOTE
• An adapter kit, part number 383EEL9001B, may
be purchased from your LG retailer. This kit
contains duct components necessary to change
the appliance vent location.
• Right-side venting is not available on gas models
(same side as gas connection).
• Bottom venting is not available on stacked or
integrated stacked models.
Side Venting
1
INSTALLATION
a
Hot lead (black and red)
b
Neutral wire (white)
c
External ground wire (if required by local
codes)
d
Wire from the appliance harness
e
Ground screw (green)
WARNING
Remove the rear exhaust duct retaining screw
a
and pull out the exhaust duct
19
b
.