Customer
Responsibilities
Before Dailyor
each
after
Every Every
each
40
100
Yeady
use
use
hours hours
Check Safety Valve
Drain Tank
Air Filter
1(1)
Air compressor
pump intake
and exhaust valves
1- more frequent in dusty or humid conditions
Risk of Unsafe
Operation. Unit
cycles automatically
when power is
on. When servicing, you may be
exposed to voltage sources,
compressed
air, or moving parts.
Before servicing unit unplug or
disconnect
electrical supply to the
air compressor,
bleed tank of
pressure, and allow the air
compressor
to cool.
To ensure efficient operation and
longer life of the air compressor, a
routine maintenance
schedule should
be prepared and followed. The
following
routine
maintenance
schedule is geared to a unit in a
normal working environment
operating
on a daily basis. If
necessary, the schedule should be
modified to suit the conditions
under
which your compressor
is used. The
modifications
will depend upon the
hours of operation and the working
environment.
Compressor
units in an
extremely dirty and/or hostile
environment
will require a greater
frequency of all maintenance checks,
NOTE: See "Operation"
section for
the location of controls.
To Check
Safety
Valve
Risk of Bursting. If
the safety valve
does not work properly, over-
pressurization
may occur, causing
air tank rupture or an explosion.
1,
Before starting compressor, pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve is
stuck or does not operate
smoothly, it must be replaced
with the same type of valve.
To Drain Tank
1.
Set the On/Auto/Off
lever to
"OFF" and unplug unit.
2.
Pull the regulator knob out and
turn counterclockwise to set the
outlet pressure to zero.
3.
Remove the air tool or
accessory,
4.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
5.
Drain water from air tank by
opening drain valve (counter-
clockwise) on bottom of tank.
_Risk
of Bursting,
Water will
condense in the air tank. If not
drained, water will corrode and
weaken the air tank causing a risk
of air tank rupture.