CUTTERHEAD
GUARD ASSEMBLY
Figure 19
1.
Remove the screw from the post (C) of the cutter-
head guard (A). See Figure 18.
Cutterhead Guard
2.
Attach the cutterhead guard (A) to the jointer/planer
(B) by locating the post of the guard through the hole
in the infeed table. See Figure 18.
Figure 18
A
C
A
SCREW
B
,
,
,
D
C
Turn knob (D) on underside of the hole to provide
tension on the spring before inserting post. The
spring must engage in the slot of the post. NOTE:
This spring allows the cutterhead guard to return
over the cutterhead after the cut has been made.
See Figure 18.
Check spring tension on the guard.
If the tension is
too loose or too tight, adjust the spring by removing
the guard and rotating the knob. Then replace the
guard, using STEP 2 above.
Thread screw removed in STEP 1 into cutterhead
guard post. This screw keeps the guard from being
removed.
BACK PANEL ASSEMBLY
,
Pull the power cord (D) and cover plate (A) through
the rectangular opening (B) in the back panel (C).
Assemble the power cord cover plate to the back
panel. See Figure 19.
Back Panel
#10-24 x 3/8" Phillips Head Flange Screw (qty. 2)
,
Assemble back panel to enclosed stand with screws
provided. Position the back panel to the stand so
that the power cord plate is to the top left hand side.
#10-24 x 3/8" Phillips Head Flange Screw (qty. 12)
DUST CHUTE
OUTLET
ASSEMBLY
NOTE: If dust collection is required, attach the supplied
dust outlet. This outlet fits a standard 4" diameter dust
collection hose.
Attach the dust outlet to the enclosed stand over the
dust chute.
Dust Chute Outlet
#10-24 x 3/8" Phillips Head Flange Screw (qty. 4)
CHANGING
MOTOR VOLTAGE
The motor supplied with this Jointer/Planer
is dual
voltage 115/230-Volt, single phase. The motor is wired
for 115-Volt operation.
If you choose 230 volt to operate
your machine, the following instructions must be
followed.
r!lVlVl_,1 _3 _II _[e.]cB
If you are unsure of electrical connections, contact a
certified electrician. All local and state codes must be
maintained.
Refer to GROUNDING
INSTRUCTION section before
proceeding:
1.
DISCONNECT
THE JOINTER/PLANER
FROM THE
POWER SOURCE.
2.
Remove the power cord cover plate from rear panel,
the rear panel of the enclosed stand and the junction
box cover on the motor.
3.
The motor with this Jointer/Planer has six motor leads
for 115-Volt operation.
Reconnect the leads as
shown on the motor identification label for 230-Volt.
14