Installation
Instructions
INSTALLING THE WATER LINE (CONT.)
Install the shutoff valve on the nearest frequently
used drinking water
line.
[] SHUT OFF THE MAIN WATER SUPPLY
AND UNPLUG REFRIGERATOR
Turn on the nearest faucet (counterclockwise)
long
enough to clear the line of water.
[-_ DRILL THE HOLE FOR THE VALVE
Choose a location for the valve that is easily
accessible.
It is best to connect
into the side of a
vertical water pipe. When it is necessary
to connect
into a horizontal
water pipe, make the connection
to
the top or side, rather than at the bottom, to avoid
drawing
off any sediment from the water pipe.
Drill a 1/4" hole in the water
pipe (even if using a self-
piercing valve), using a sharp bit. Remove any burrs
resulting from drilling the hole in the pipe. Take care
not to allow water
to drain into the drill. Failure to
drill a 1/4" hole may result in reduced
ice production
or smaller cubes.
%
FASTEN THE SHUTOFF VALVE
Fasten the shutoff valve to the cold water pipe with
the pipe clamp.
Tighten the clamp screws until the sealing washer
begins to swell.
Pipe Clam_
Clamp
Screw_
Saddle-Type -j-/
Shutoff Valve
NOTE: Do not overtighten
or you may crush the
tubing.
!
Washer
--_
Inlet End
Vertical
Cold
Water Pipe
NOTE: Commonwealth
of Massachusetts
Plumbing
Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted
in Massachusetts.
Consult with your licensed plumber.
[] ROUTE THE TUBING
Route the tubing between
the cold water line and the
refrigerator.
Route the tubing through
a hole drilled in the wall or
floor (behind the refrigerator
or adjacent
base cabinet)
as close to the wall as possible.
NOTE: Be sure there is sufficient
extra tubing (about 8
feet [244 cm] coiled into 3 turns of about 10" [25 cm]
diameter) to allow the refrigerator
to move out from
the wall after installation.
%
CONNECT THE TUBING TO THE VALVE
Place the compression
nut and ferrule (sleeve) for
copper tubing onto the end of the tubing and connect
it to the shutoff valve.
Make sure the tubing is fully inserted
into the valve.
Tighten the compression
nut securely.
For plastic tubing from a GE SmartConnect
TM
Refrigerator
Tubing kit, insert the molded end of the
tubing into the shutoff valve and tighten
compression
nut until it is hand tight, then tighten one additional
turn with a wrench.
Overtightening
may cause leaks.
)ression
Nut
Saddle@
Shutoff Valve
SmartConnecC
Tubing
Packing Nut--
Outlet Valve._
--
Ferrule (sleeve)
NOTE: Commonwealth
of Massachusetts
Plumbing
Codes 248CMR shall be adhered
to. Saddle valves
are illegal and use is not permitted
in Massachusetts.
Consult with your licensed plumber.
% FLUSH OUT THE TUBING
Turn the main water supply on (counterclockwise) and
flush out the tubing until the water is clear.
Shut the water off at the water valve after about
one quart (1 liter) of water
has been flushed through
the tubing.
__