Air filters are not fitted to the compressor.
Screw in the air filters (4) before starting the compressor.
The compressor allows compressed air to be supplied via 2
types of connection:
• For fixed installation with rigid pipework, use the outlets
(2) on the tank tops (7):
1. Remove the cap with a hex key;
2. Screw on the fixed pipe connection fitting.
The outlets at the top allow the use of pipes with larger
diameters.
It is not possible to regulate the discharge pressure.
• Outlet valve with quick-release coupling (12):
1. Insert the air hose or air tools fitting into the quick-
release coupling.
These outlet valves allow the adjustment of the outlet
pressure.
The air compressor is a commonly used machine in
construction sites, repair shops or industries. It provides
compressed air for the operation of various machines, such
as air or spray guns and pneumatic tools.
While operating a compressor, you should take into
consideration some care and procedures of use:
▪ Never touch the cylinder head, the ventilation slots or
the compressed air pipes, as these parts reach high
temperatures during operation. After stopping the
compressor, wait some minutes until the parts cool
down;
▪ Never place inflammable objects or nylon and fabric
objects near and/or over the compressor;
▪ The pipes or hoses connected to the compressor must
have
the
same
displacement and pressure;
▪ Never turn on the compressor if the air filter is not fitted;
▪ Never change the safety valve neither the air tank;
▪ If there are ball shut-off valves in the compressor
connected to the fixed network, they must be opened
slowly. Never open the ball valve quickly as it is
discharging pressure that can damage equipment or
tools;
▪ When using the compressor for painting, never work
within 10m of the compressor. Use hoses to work at a
safety distance from the compressor;
▪ The compressor can only be started up in environments
with temperatures between +5°C and +45°C.
Before starting the compressor, you must ensure that
all parts are properly assembled.
characteristics
regarding
air