5.2 Frequency measurement
To perform frequency measurement:
set the rotary switch at
press MODE button, until symbol Hz is shown on the display,
connect black test lead to COM terminal, and red test lead to
VΩHz%
contact the tips of test probes to the points of measurement,
read the measurement result on the display.
5.3 Measurement % of duty cycle (pulse fill-
ing indicator)
To perform the measurement:
set the rotary switch at
press MODE button, until symbol % is shown on the display,
connect black test lead to COM terminal, and red test lead to
VΩHz%
contact the tips of test probes to the points of measurement,
read the measurement result on the display.
5.4 DC voltage measurement
WARNING
Electric shock hazard. The ends of measuring
probes, due to their length, may not reach the live
parts inside some network connections of low-
voltage electrical equipment, because the contacts
are arranged inside the sockets. In such a case, the
read-out will be 0 V with the simultaneous presence
of voltage in the socket.
Before acknowledging the absence of voltage in the
socket make sure that the ends of the of the probe
touch the metal contacts inside the socket.