7. Adjust the height of the inside chimney to the position of the inside chimney bracket
and fix on it with 2pcs ST4*8mm screws. Fix the outside chimney onto the hood body
with 2pcs ST4*8mm screws.See Pic 7.
HINTS FOR EXHAUST DUCT INSTALLATION
The following rules must be strictly followed to obtain optimal air extraction:
• Keep exhaust duct short and straight
• Do not reduce the size or restrict the expansion pipe.
• When using the flexible duct always install the duct pulled taut to minimize pressure
loss
• Failure to observe these basic instructions will reduce the performance and increase
noise levels of the range hood.
• Any installation work must be carried out by a qualified electrician or competent
person.
•Do not connect the ducting system of the hood to any existing ventilation system
which is being used for any other appliance ,such as warmer tube, gas tube , hot wind
tube.
•The angle of the bend of the ventilation pipe should not be less than 120º; you must
direct the pipe horizontally, or, alternatively, the pipe should go up from the initial point
and should be led to an outer wall.