TROUBLESHOOTING
Fault
Light on, but motor
does not work
Light
does
not
work, motor does
not work
Oil leakage
Lights not working
Insufficient suction
The Cooker hood
inclines
NOTE:
Any electrical repairs to this appliance must conform to your local, state and
federal laws.Please contact the service centre if in any doubt before
undertaking any of the above.Always disconnect the unit from the power source
when opening the unit.
Possible Cause
Fan switch turned off
Fan switch failed
Motor failed
House fuses blown
Mains power cable is loose or
disconnected
One way valve and the outlet
are not tightly sealed
Leakage from the connection of
chimney and cover
Broken or faulty bulbs
The
distance
between
cooker hood and the gas top is
too far
The fixing screw is not tight
enough
Solution
Select a fan switch position.
Contact service center.
Contact service center.
Reset/Replace fuses.
Refit mains power cable to
power outlet.
Switch power outlet on.
Take down the one way valve
and seal with sealant.
Take chimney down and seal.
Replace
blubs
instruction.
the
Refit the cooker hood to the
correct distance.
Tighten the hanging screw and
make it horizontal.