10. Possible causes of failure
Problem
The compressor
does not start.
The compressor
starts but there is no
pressure.
The compressor
starts, pressure is
shown on the pres-
sure gauge, but the
tools do not start.
Anl_TE_AC_18_75_Li_OF_SPK13.indb 20
Anl_TE_AC_18_75_Li_OF_SPK13.indb 20
GB
Cause
1. No power supply
2. Outside temperature is too low.
3. Motor is overheated.
1. The non-return valve leaks.
2. The seals are damaged.
3. The drainage cock for condensati-
on water has a leak.
1. The hose connections have a leak.
2. A quick-lock coupling has a leak.
3. Insuffi cient pressure set on the
pressure regulator.
- 20 -
Solution
1. Check the rechargeable batteries
2. Never operate with an outside tem-
perature of below +5° C.
3. Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
1. Have a service center replace the
non-return valve.
2. Check the seals and have any da-
maged seals replaced by a service
center.
3. Check the drainage cock and repla-
ce if necessary.
1. Check the compressed air hose
and tools and replace if necessary.
2. Check the quick-lock coupling and
replace if necessary.
3. Increase the set pressure with the
pressure regulator.