6. Installation
The appliance is supplied with a NEMA 5-15 grounded plug.
WARNING: PLEASE DO NOT DISASSEMBLE THIS
APPLIANCE YOURSELF. ELECTRIC ELEMENTS WILL BE
EXPOSED AND THERE IS A RISK OF ELECTROCUTION.
POSITIONING OF APPLIANCE
• Do not install this appliance in a very damp, hot place or
near heat source.
• Place the appliance on a flat and even surface.
• Install the appliance in a dry place to avoid damage,
moisture or rust.
• Do not use this appliance outdoors. This appliance is
only suitable for use indoors.
• Do not overhang the power cord and/or water tray off a
table, counter or other surface and avoid contact with
hot surfaces.
• WARNING: DO NOT INSTALL THIS APPLIANCE IN
DIRECT SUNLIGHT.
• Ensure that the ventilation on both sides is never blocked
or covered.
TROUBLESHOOTING
Condition
Machine will not start.
Machine will not dispense.
Descale warning symbol on screen.
Refill water warning symbol on screen.
Change filter warning symbol on screen
(will illuminate after 26.4 gallons/100L)
Code
Operation
EAC
Lock + boil light blink
DSO
Lock + 205°F light blink
ENTC
Lock + 200°F light blink
E09
Lock + 190°F light blink
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation.
AUH012: Electrical rating input: 120V~ 50-60Hz 1500W. Rated service flow: 3.5 Liters per day (LPD)/0.77 Gallons per day
(GPD). Operating temperatures 5�C (min) - 30�C (max)
• WARNING: When positioning the appliance, ensure the
supply cord is not trapped or damaged.
• WARNING: Do not locate multiple portable socket-outlets
or portable power supplies at the rear of the appliance.
Possible cause
Appliance is unplugged.
Appliance requires rinse
cycle.
Appliance needs descaling.
Water tank is empty.
Filter life expired.
5
Solution
Ensure the power cord is inserted in the
appliance and the plug is securely placed
into the socket.
Press and hold the rinse/descale button
for more the 0.5 seconds.
Descale appliance using instructions in
manual.
Refill water tank following the descaling
instructions.
Change filter following the Aqua Optima
filter instructions. Reset filter warning
symbol by holding for 3 seconds.
Error Description
Wrong input AC power
Running without water
NTC failure
No power to element/heater