5 Maintenance

5.3 Cleaning the particle trap

A
B
1
13

5.4 Cleaning the hygienic exhaust filter

A
14

5.5 Spare parts and accessories

ATTENTION:
Only use original spare parts from the scope of delivery or those that you
have acquired by reordering.
Ordering address:
page 48, „International Service".
Further information:
www.dirtdevil.de
The following accessories and spare parts can be reordered:

5.6 Before you send in the appliance

WARNING:
Danger of injury! Never use a defective appliance! Always switch off the
appliance and disconnect it from the mains before starting troubleshoot-
ing
chapter 4.3, „Switching off".
Before contacting your authorised Royal dealer, Royal service partner or
appliance market or sending in the appliance, first follow the procedure in
the following table to check if you can solve the problem yourself.
Problem
Solution
The appli-
The socket does not carry current.
ance will
Test the vacuum cleaner at another socket which you are
not start
sure carries current.
Power cord is damaged. Have the power cord replaced by
Royal Appliance Customer Service, address,
„International Service".
The vacu-
The overheating protection has tripped (possibly due to
um cleaner
blocked suction channels, filters, or similar).
stops sud-
Switch the appliance off and pull the plug out of the socket.
denly.
Remove the cause of overheating (e. g. by disassembling
telescopic tube and suction hose and removing the obstacle
and/or cleaning filters). Wait for about 45 minutes. After the
appliance has cooled off, you may switch it on again.
Cleaning
The dust container is full.
indicator
Empty / clean the dust container,
(Fig. 1/13,
and cleaning the dust container" and
optional)
ing the particle trap"
lights up.
1. Switch off the appliance,
2. Remove the dust container
dust container".
3. If dirt is visible in the suction channel (Fig. 13/A1), lay the appliance on
its side.
4. Open the particle trap by twisting it off (Fig. 13/B). The dirt will fall out
of the opening. If necessary, help a bit by hand.
5. Empty the dirt into a dustbin.
6. Close the cleaned suction channel by refitting and fastening the particle
trap.
7. If you haven't done this by now, firmly push the dust container back into
its receptacle. Check that it is securely fitted..
1. Switch off the appliance,
B
2. Push the release catch of the exhaust filter cover down (Fig. 14/A) and
fold down the exhaust filter cover.
3. Remove the exhaust filter (Fig. 14/B).
4. Tap the exhaust filter over a dustbin for a rough cleaning. Remove larg-
er agglomerations of dirt by hand.
5. Remove residual dust with a soft brush, e.g. the supplied furniture
brush.
6. Ifthe filter is damaged or deformed, replace it.(ordering information
chapter 5.5, „Spare parts and accessories").
7. Place the clean/new exhaust filter back into its fitting.
8. Attach the exhaust filter cover at the bottom side first and then fold it
upwards.
Item number
5050001
5050002
5050003
M203
M209
Problem
The clean-
ing results
are unsat-
isfactory in
spite of the
appliance
working
correctly.
page 48,
chapter 5.1, „Emptying
chapter 5.3, „Clean-
chapter 4.3, „Switching off"
chapter 5.1, „Emptying and cleaning the
chapter 4.3, „Switching off"
Description
1 Dual motor protection filter (2 pieces: foam plastic filter
element (Fig. 1/19) and filter holder (Fig. 1/20))
1 hygienic exhaust filter
1 particle trap
Item number
1 parquet brush
M219
1 mini turbo brush
1 turbo brush
M232
1 long crevice nozzle
Solution
The bypass vent (Fig. 1/24) is open.
Close the bypass vent (Fig. 1/24).
The attached nozzle is unsuitable.
Change the nozzle
chapter 3.2, „Selecting the proper noz-
zle"
The position of the "carpet/hard floor" selector (Fig. 1/28) is
unsuitable.
Set the "carpet/hard floor" selector (Fig. 1/28) to the correct
position for the type of floor,
chapter 4.2, „Vacuum clean-
ing", step 4.
The dust container is full.
Empty / clean the dust container
chapter 5.1, „Emptying
and cleaning the dust container".
The filter is dirty.
Change/clean the respective filter
chapter 5.2, „Cleaning
the cyclone unit and the dual motor protection filter" or
chapter 5.4, „Cleaning the hygienic exhaust filter".
Nozzle, telescopic tube or suction hose are blocked.
Remove the obstacle. If necessary, use a long wooden stick
(e.g. a broomstick) to do this.
Description
15