• HSA Automatic Hot Start
Display B shows the message OFF = Off. Pressing the knob A
causes the display B to show the message On = Active.
If this function is activated, the following messages to appear in
sequence:
-
START CURR
Range 1-20 (10-200%) of the wire speed corresponding to the
welding current set using knob A in the welding programs.
-
S.C. TIME
This is the duration, expressed in seconds, of the previously
set start current. Range 0.1-10 sec.
-
SLOPE TIME
Range 0.1-10 sec. Defines the interface time between the first
current (START CURR) and the welding current set using knob
A in the welding programs.
• CRA Crater Current
Display B shows the message OFF = Off. Pressing the knob A
causes the display B to show the message On = Active.
If this function is activated, the following messages to appear in
sequence:
-
SLOPE TIME
Range 0.1-10 sec. It defines the interface time between the
welding current and the crater current set using knob A in the
welding programs.
-
CRATER CURR
Range (10-200%) of the wire speed corresponding to the
welding current set using knob A in the welding programs.
-
C.C. TIME
This is the duration, expressed in seconds, of the previously
set Crater current. Adjustment range 0.1–10 sec.
• Inductance
Adjustment can vary from -9.9 to +9.9. Factory setting is zero. If
the figure is negative, the impedance drops and the arc becomes
harder, while if it increases, the arc is softer.
To access this function, simply highlight it using the knob A and
press it for less than 2 seconds. The display screen B shows the
adjustment bar. The figure can be changed and confirmed by
pressing the knob A for less than 2 seconds.
• AUTO burnback
The adjustment can vary from -9.9 to +9.9. Its purpose is to
adjust the length of the wire coming out of the gas nozzle after
welding. A positive figure corresponds to greater wire burning.
Default is Auto.
To access this function, simply highlight it using the knob A and
press it for less than 2 seconds. The display screen B shows the
adjustment bar. The figure can be changed and confirmed by
pressing the knob A for less than 2 seconds.
• Soft Start AUTO
Adjustment can vary from 0 to 100%. This is the wire speed
expressed in percentage of the speed set for welding, before the
wire touches the piece to be welded.
This adjustment is important to obtain always good starts.
Default is Auto.
To access this function, simply highlight it using the knob A and
press it for less than 2 seconds. The display screen B shows the
adjustment bar. The figure can be changed and confirmed by
pressing the knob A for less than 2 seconds.
• Pre Gas
The adjustment can vary from 0 to 10 seconds.
To access this function, simply highlight it using the knob A and
press it for less than 2 seconds. The display screen B shows the
adjustment bar. The figure can be changed and confirmed by
pressing the knob A for less than 2 seconds.
PreGas
PostGas
• Post Gas
The adjustment can vary from 0 to 25 seconds.
To access this function, simply highlight it using the knob A and
press it for less than 2 seconds. The display screen B shows the
adjustment bar. The figure can be changed and confirmed by
pressing the knob A for less than 2 seconds.
9
0.1 s
3.1 s