5. Tighten chuck jaws securely into drive bar.
Drive bar must be centered in front chuck
WARNING
jaws. Drive bar must be securely held in chuck.
NOTE! Before transporting the 300 Compact using the
No. 250 Stand, the 916 Roll Groover and 916
Roll Groover Adapter Bracket MUST be disas-
sembled and removed from the machine. If left
intact, these items will not allow the No. 250
Stand to lock in the folded position.
Pre-Operation Inspection
WARNING
Do not use this roll groover with a power drive/-
threading machine that does not have a foot switch
Before each use, inspect your roll groover and cor-
rect any problems to reduce the risk of serious
injury from crushing injuries and other causes and
prevent roll groover damage.
1. If installed on a machine, place the machine switch in
the OFF position and unplug.
2. Clean any oil, grease or dirt from the roll groover,
including the pump handle. This aids inspection and
helps prevent the machine or control from slipping
from your grip.
3. Inspect the roll groover for the following:
• Proper assembly, maintenance and completeness.
• Broken, worn, missing, misaligned or binding parts.
• Presence and readability of the warning label (see
Figure 5).
• Condition of the groove roll and drive roll. If the
drive roll knurls are dirty, clean with a wire brush.
Dirty or worn knurls can cause pipe slippage and
tracking issues during grooving.
• Any other condition which may prevent safe and
normal operation.
• If any issues are found, do not use the roll groover
until the issues have been repaired.
999-998-693.10_REV. B
916 Roll Groover
Figure 5 – Warning Label
4. Inspect and maintain any other equipment being used
per its instructions to make sure it is functioning prop-
erly. Confirm that the Power Drive or Threading Ma-
chine has a foot switch in good working condition.
Machine and Work Area Set-Up
WARNING
Set up the roll groover and the work area according to
these procedures to reduce the risk of injury from
machine tipping, crushing and other causes, and to
help prevent machine damage.
Secure roll groover to power drive or threading
machine. Properly support pipe. This will reduce the
risk of falling pipe, tipping and serious injury.
1. Locate a work area that has the following:
• Adequate lighting
• No flammable liquids, vapors or dust that may
ignite.
• Grounded electrical outlet
• Clear path to the electrical outlet that does not
contain any sources of heat or oil, sharp edges or
moving parts that may damage electrical cord.
• Dry place for machine and operator. Do not use
the machine while standing in water.
• Level ground
2. Clean up the work area prior to setting up any equip-
ment. Always wipe up any oil that may be present.
3. Place machine on a flat, level surface. Be sure the
machine, stand and groover are stable.
7