1. SAFETY GUIDE

For good performance and precise measurement, be careful with daily operation and maintenance.
> Do NOT overload the crane scale. This will damage loadcell and void warranty.
> Do NOT leave load hung on the crane scale for long. This will decrease crane scale's accuracy and shorten
loadcell's life.
> Inspect shackle and hook before using. Check clips, pins and screws regularly.
> Check battery frequently. When crane scale runs out of power, replace the dead batteries with new ones.
> Rotate load rather than crane scale if needed.
> Do NOT use crane scale under thunder or rain.
> Hang crane scale on shelf in dry and well-ventilated room. Do NOT place crane scale on the ground directly.
> Do NOT attempt to repair crane scale yourself. Contact your local representative.
2. FEATURES
This crane scale is a combination of sound and proven mechanical design, with today's most advanced
electronics to provide a superb feature set. It is versatile, reliable, accurate and easy to operate.
> Superb Quality. Strictly in accordance with GB/T11883-2002 standards, and European CE directives ISO
9001-2000
> Great Safety. Aluminum-casting case, high firm hook and shackle, dedicated weighing loadcell for safety
installation.
> Strong Reliability. Cutting-edge technology, quality integrated circuit for high performance and long-time
stability.
> Broad Applicability. Popular and applicable in storage, textile, metallurgy industry, and so forth.
> Complete Function. Resolution switch, unit conversion, auto power-off, battery inspection, etc.
> Newest LCD of 20mm. Readable up to 10m
> Design. Unmountable crane scale
3. SPECIFICATIONS
Tare Range
Manual zero
Zero tracking
Stability Time
Auto standby
Auto power off
Safety Load
Ultimate Load
Battery life
Op. Humidity
Manual de usuario | Manuel d'usager | User's guide | Benutzerhandbuch
Accuracy
Auto Zero
Overload
Battery
Display
Op. Temp.
Class III
100% F.S.
±5% F.S.
±2% F.S.
0,5 e/s
≤10 sec
Selectable
Selectable
100% F.S. + 9e
120% F.S.
400% F.S.
3*AA 1.5V batteries
≥150 hours
22 mm. LCD with backlight
-
10ºC ~ +40ºC
20% ≤90% a 20°C