QUESTIONS TO BE RUN INTO DURING WELDING
Fittings, welding materials, environment factor. supply powers maybe have something to do with welding.
User must try to improve welding environment.
A. Arc-striking is difficult and easy to pause
1. Make sure quality of tungsten electrode is high .
2. If the electrode is not dried, it will cause unstable arc, welding defect increases and the quality is
down.
3. If use extra-long cable, the output voltage will decrease, so please shorten the cable
B. Output current not to rated value,
When power voltage departs from the rated
rated value; when voltage is lower than rated value, the max output may lower than rated value.
C. Current is not stabilizing when machine is been operating,
It has something with factors as following
1. Electric wire net voltage has been changed .
2. There is harmful interference from electric wire net or other equipment
D. Too much spatter when use MMA welding,
1. Maybe current is too big and stick's diameter is too small.
2. Output terminal polarity connection is wrong, it should apply the opposite polarity at the normal
technics, which means that the stick should be connected with the negative polarity of power source,
and work piece should be connected with the positive polarity. So please change the polarity.
MAINTENANCE
1. Remove dust by dry and clean compressed air regularly, if welding machine is operating in
environment where is polluted with smokes and pollution air, the machine need remove dust every
month.
2. Pressure of compressed air must be within the reasonable range in order to prevent damaging to
small components of inner-machine.
3. Check internal circuit of welding machine regularly and make sure the circuit connections are
connected correctly and tightly (especially plug-in connector and components). If scale and rust are
found, please clean it, and connect again tightly.
4. Prevent water and steam from entering into the machine. If that happens, please blow ii dry and
check insulation of machine
5. If welding machine will not be used for long time. it must be put into the packing box and stored in dry
and clean environment.
value,
it will make the output current not matched with
53