Space required in use ²
H2
mm
W2
mm
D2
mm
² the height, width and depth of the appliance
including the handle, plus the space
necessary for free circulation of the cooling
air
Overall space required in use ³
H2
mm
W3
mm
D3
mm
³ the height, width and depth of the appliance
including the handle, plus the space
necessary for free circulation of the cooling
air, plus the space necessary to allow door
opening to the minimum angle permitting
removal of all internal equipment
3.2 Location
This appliance is not intended to be used as
a built-in appliance.
In case of different installation from
freestanding respecting space required in use
dimensions, the appliance will function
correctly but energy consumption might
increase slightly.
To ensure appliance's best functionality, you
should not install the appliance in the nearby
of the heat source (oven, stoves, radiators,
cookers or hobs) or in a place with direct
sunlight. Make sure that air can circulate
freely around the back of the cabinet.
This appliance should be installed in a dry,
well ventilated indoor position.
To ensure best performance, if the appliance
is positioned below an overhanging wall unit,
the minimum distance between the top of the
cabinet shall be maintained. Ideally, however,
the appliance should not be positioned below
overhanging wall units. One or more
adjustable feet at the base of the cabinet
ensure that the appliance stands level.
If you position the appliance against the
1900
wall, use back spacers provided or keep
the minimum distance indicated in the
600
installation instructions.
718
If you install the appliance next to a wall,
refer to the installation instructions to
understand the minimum distance
between the wall and the side of the
appliance where door hinges are to
provide enough space to open the door
1900
when the internal equipment is removed
(e.g. when cleaning).
649
This appliance is intended to be used at
1224
ambient temperature ranging from 10°C to
43°C.
The correct operation of the appliance
can only be guaranteed within the
specified temperature range.
If you have any doubts regarding where
to install the appliance, please turn to the
vendor, to our customer service or to the
nearest Authorised Service Centre.
It must be possible to disconnect the
appliance from the mains power supply.
The plug must therefore be easily
accessible after installation.
3.3 Electrical connection
• Before plugging in, ensure that the voltage
• The appliance must be earthed. The
CAUTION!
CAUTION!
and frequency shown on the rating plate
correspond to your domestic power
supply.
power supply cable plug is provided with a
contact for this purpose. If the domestic
power supply socket is not earthed,
connect the appliance to a separate earth
in compliance with current regulations,
consulting a qualified electrician.