3. Intended Use
Always observe the maximum load capacity of the magnet according to FX manual.
The load limit is determined by the carrying capacity of the magnet and the limitation
by the workpiece according to FX determined operating instructions and can signifi-
cantly be below the mechanical maximum capacity of the LT system.
3.1 General instructions before use
• Before each use, check the contact surfaces of both the magnet and that of the Workpi-
ece. The contact surfaces must be clean and flat ! (Also note the Operating Instructions for
FX Lifting magnets)
• ALWAYS SAVE THE DETENT PINS WITH RELATED SPLINT!!!
3.2 Uses FX-LT Magnetic Truss
2 pieces FX (V) thin plate magnets with a slight distance Truss and a 2-strand chain slings
allow the loading and unloading of machines with plates from 4mm thickness, up to a
Maximum dimension of 5000x2500mm. (Note Page 60) The FX-LT lightweight Truss is
particularly stable due to their customized design. Note that the truss must be placed on the
workpiece, the workpiece can be transported inherently rigid and vibration free. Note this
the diagrams below.
Length
Material thickness
3.3 Conversion to single use of the FX lifting magnets
With a few simple steps it can be changed from the Truss application in the individual
magnetic application. For this remove the linch pin off the bolt and tighten the bolt. Pull the
lifting magnets down from the suspension of the distance Truss. Now the Lifting Magnet
can be used as a default device. Note that the linch pin and bolt must be inserted for every
consignment.
CONSIDER LOAD TABLES AND THE INSTRUCTIONS FOR FX LIFTING MAGNETS!!
4. Maintenance
This maintenance schedule is in compliance with the rules for the FX-HV system, see page