Descargar Imprimir esta página

AVE V44 VIIP-RELAY Manual De Instrucciones página 2

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 4
VIIP-RELAY – IP RELAY MODULE FOR V44 SMART SYSTEM
ENG
1) WARNINGS AND PRECAUTIONS FOR USE
These devices can only be used with an AVE V44 SMART video intercom system. They can be installed inside rooms, within the indicated temperature limits. Opening the devices results in the immediate
forfeiture of the industrial warranty. Any other use is to be considered inappropriate and prohibited. The manufacturer shall not be liable for damage resulting from inappropriate use of the product, other than
as provided for in this manual. Please read this manual carefully in all its parts.
1.1) DECLARATION OF CONFORMITY
The Manufacturer, AVE SPA, declares that the product has been manufactured in compliance with the following regulations/directives:
Reference standards
• RoHS Directive 2011/65/EU
• REACh Regulation (EC) No. 1907/2006
For performance
• EN 62820-1-2:2017 Building intercom systems - Part 1-2: System requirements - Building intercom systems using Internet Protocol (IP)(Except para. 5.4 Safety requirements)
For the EMC Directive 2014/30/EU
In addition to the requirements of Standard EN 62820-1-1:2016 para. 5.6:
• EN 55032:2015 +A1:2020 Electromagnetic compatibility of multimedia equipment - Emission requirements
• EN 55035:2017 +A11:2020 Electromagnetic compatibility of multimedia equipment - Immunity requirements
• EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase)
• EN 61000-3-3:2013 Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage variations, voltage fluctuations and flicker in public low-voltage supply systems, for equipment
with rated current ≤16 A per phase and not subject to conditional connection
For the LV Directive 2014/35/EU
• EN 62368-1:2014 Audio/video, information and communication technology equipment – Part 1: Safety requirements
• EN 60669-2-1:2021 Non-automatic switchgear for household and similar fixed electrical installations. Part 2-1: Special requirements - Electronic control devices
2) GENERAL INFORMATION
The device is an IP module with 2 monostable relays with N.C. and N.O. output contacts. The module can be programmed using the AVE V44 CONFIG configuration software available for PCs running
Windows® 10 or higher. The device can be associated with outdoor stations and IP indoor stations of the V44 SMART video intercom range to manage:
• Outdoor station auxiliary relay;
3) INSTALLATION, POSITIONING AND FIXING
VIIP-RELAY is a DIN rail device (2 DIN modules). It can be installed indoors and within the temperature and humidity limits indicated in the technical characteristics table of the device. The device can be
powered via a 48Vdc PoE switch or via a +24Vdc power supply.
4) OPERATION
The device is programmed using the AVE V44 CONFIG configuration software. It is possible to associate only one function (among those listed below), with the VIIP-RELAY device: it is therefore not possible
to configure, for example, relay no.1 as a call repeater and relay no.2 as an outdoor station auxiliary relay. If a primary power supply via PoE switch is used, make sure that the total power consumption of
all IP devices is less than the maximum current that can be supplied by the switch. The device can be configured in the following modes:
OUTDOOR STATION AUXILIARY RELAY
Up to two devices (4 total relays) associated with an external IP plate can be installed. The devices must be installed on the same data network where the external plates reside.
The device automatically configures its own IP address (consistent addresses for association with the outdoor stations) and it cannot be changed.
Select via the software application: • The closing time of each device relay; • "Building" or "Villa" function; • The ID to the device (1-32 Building) (1-64 Villa);
Attention: in order for the outdoor video intercom station to be able to control the VIIP-RELAYs, it is necessary that the configuration of the outdoor station via the V44 CONFIG software
specifies the IDs of the relays to be managed.
CALL REPETITION RELAY
It is possible to install 1 device for each apartment. The relay can be assigned an IP address such that the TS-SMART can detect it through the LAN network.
The association of the relay with an apartment can be configured using the V44 CONFIG configuration software: the relay must have the same apartment address as the indoor station. The relay actuates
the load associated with it when a call reaches the indoor station of the apartment with which it is associated. The relays are closed according to the pattern shown below.
PRIVATE AUXILIARY RELAY
This function is available only in association with TS-SMART7, TS-SMART10, TS-SMART18 monitors; up to 10 relays can be associated with an apartment. The relays work in monostable mode: the
contact closing time can be changed using the V44 CONFIG configuration software. "Private auxiliary relay" management requires:
• With the V44 SMART video intercom system: an IP address must be assigned to the relay such that the TS-SMART can detect it through the Wi-Fi network with which it is associated.
• Without the V44SMART SMART video intercom system: an IP address must be assigned to the relay such that the TS-SMART can detect it either through the wired LAN or through the Wi-Fi network
with which it is associated.
For the configuration and management of the device from the TS-SMARTxx touch screen:
• Activate auxiliary relay management in the menu: Settings/Advanced parameters/Main page management; • On the home page, tap on the "Relay" key; • Tap on the "Add relay" key and fill in all the
fields (enter as the IP address the one previously associated with the VIIP-RELAY using the V44 CONFIG configuration software); • Save the configuration;
To manage the auxiliary relays, tap on the "Relays" icon and tap on the icon corresponding to the implementation to be activated.
5) LOADS THAT CAN BE MANAGED BY THE RELAYS
The device can manage the following loads:
Ohmic load (cos 1)
6 A
Incandescent lamp
6 A
Fluorescent lamp
0.5 A
LED
100 W (check that the "inrush current" is within the described limits)
6) TERMINALS and LEDs
Terminal
Meaning
Terminal 1
NO normally open contact relay 1
Terminal 2
COM common contact relay 1
Terminal 3
NC normally closed contact relay 1
Terminal 4
NO normally open contact relay 2
12) TECHNICAL CHARACTERISTICS
With the aim of improving its products, AVE S.p.a. reserves the right to modify any technical characteristics at any time and without prior notice while retaining functionality and intended use. In addition to
what has already been described, the following technical characteristics refer to the ambient temperature of 20°C (+/- 5°C) and to normal use of the device (residential environment).
PoE power supply
Power supply
PoE stand-by power consumption
PoE in-service power consumption
+24VDC stand-by power consumption
+24VDC in-service power consumption
TO DOWNLOAD THE COMPLETE MANUAL OF THE 2-WIRE SYSTEM, SCAN THE QR CODE SHOWN ON THE DRAWINGS PAGE
• Call repetition relay;
• Private auxiliary relay;
CFL
Electronic transformers
Motors
Terminal
Meaning
Terminal 5
COM common contact relay 2
Terminal 6
NC normally closed contact relay 2
Terminal 7
+24 VDC power supply
Terminal 8
Power supply GND
+48VDC
Environmental class (in accordance with Standard EN50131)
On-board relay
+24VDC
Operating temperature/humidity
24 mA
50 mA
Weight
40 mA
IP
80 mA
Dimensions (WxHxD)
100 W
4 A
2 A
LED L1:
green normally ON. Flashing during the time with
relay 1 energised.
LED L2:
green normally ON. Flashing during the time with
relay 2 energised.
III
2 with potential-free changeover contact 10A/230VAC
-10°C ... +40°C - Rh 95%
94 g
20 (40 if installed)
2 DIN modules