WIRING
SUPPLY
On the power supply line use appropriate time-lag fuses according to the voltage.
ALARMS ACTIVATION
PNP
To activate the alarms in PNP
mode, use the dedicated pin
(VOUT) and not the positive of
the power supply
-
+
-
+
To activate the alarms in NPN
mode, use the dedicated pin
(GND) and not the mass of the
power supply
ALM1 has priority over ALM2, ALM3 and ALM4
ALM2 has priority over ALM3 and ALM4
ALM3 has priority over ALM4
Jumper to move per connection
PNP or NPN
1 PWR: Power
2 PWR: Power
GND: Ground
CMD LAMP: Not available
VOUT: Aux Voltage
ALM4: Alarm n°4
ALM3: Alarm n°3
ALM2: Alarm n°2
PWR
ALM1: Alarm n°1
COM: Common
24Vdc
-
+
-
+
NPN
-
+
-
+
EXTERNAL POWER SUPPLY
No Jumper
-
+
-
+
1 PWR: Power
2 PWR: Power
GND: Ground
CMD LAMP: Not available
VOUT: Aux Voltage
ALM4: Alarm n°4
ALM3: Alarm n°3
ALM2: Alarm n°2
ALM1: Alarm n°1
COM: Common
-
+
-
+