Configuration - BFT MOOVI 30S / 30-50 RMM Instrucciones De Uso

Automatismos electromecanicos para barréras vehicular
Ocultar thumbs Ver también para MOOVI 30S / 30-50 RMM:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
10) PROGRAMMING
The control panel provided with a microprocessor is supplied with function
parameters preset by the manufacturer, suitable for standard installations.The
predefined parameters can be altered by means of either the incorporated
display programmer or UNIPRO.
In the case where programming is carried out by means of UNIPRO, carefully
read the instructions relating to UNIPRO, and proceed in the following way.
Connect the UNIPRO programmer to the control unit through the UNIFLAT
accessory (See fig. 20). Enter the "CONTROL UNITS" menu, and the "PA-
RAMETERS" submenu, then scroll the display screenfuls using the up/down
arrows, and set the numerical values of the parameters listed below.
For the function logics, refer to the "LOGIC" submenu.
In the case where programming is carried out by means of the incorporated
programmer, refer to Fig. A and B and to the "configuration" paragraph.

11) CONFIGURATION

The display programmer is used to set all the LEO-MV control panel func-
tions.
The programmer is provided with three pushbuttons for menu scrolling and
function parameter configurations (Fig. 2):
+
menu scrolling/value increment key
-
menu scrolling/value reduction key
OK
Enter (confirm) key
The simultaneous pressure of the + and – keys is used to exit the active
menu and move to the preceding menu.
If the + and – keys are pressed simultaneously at the main menu level (param-
eters, logics, radio, language, self-diagnosis), programming is exited and the
display is switched off (the OK message is displayed).
The modifications made are only set if the OK key is subsequently
pressed.
When the OK key is pressed for the first time, the programming mode is entered.
The following pieces of information appear on the display at first:
-
Display Software version
-
Control unit Software version
-
Number of total manoeuvres carried out (the value is expressed in
thousands, therefore the display constantly shows 0000 during the first
thousand manoeuvres)
-
Number of manoeuvres carried out since the latest maintenance opera-
tion (the value is expressed in thousands, therefore the display constantly
shows 0000 during the first thousand manoeuvres)
-
Number of memorised radio control devices.
When the OK key is pressed during the initial presentation phase, the first
menu (parameters) can be accessed directly.
Here follows a list of the main menus and the respective submenus available.
The predefined parameter is shown between square brackets [ 0 ].
The writing appearing on the display is indicated between round brackets.
Refer to Figures A and B for the control unit configuration procedure.
11.1) Parameter Menu (PARAM)
1- Automatic Closing Time (TCA) [ 10s ]
Set the numerical value of the automatic closing time from 1 to 180
seconds.
2- Slow-down distance (slud dist) [ 005]
Set the required slow-down distance on opening and on closing between
1 and 10.
3- Alarm time (alarm. time) [ 30s ]
In the case of obstacle detection or photocell engagement, at the end of
the time set (ranging from 10s to 240s) the SCA contact is closed. The
contact is subsequently opened by the STOP command or by triggering of
the closing limit switch. Only active when the SCA Alarm logic is set to OFF.
4- Zone (zone) [ 0 ] (UNIPRO ⇒ Advanced parameters ⇒ address 1)
Set the zone number between a minimum value of 0 and a maximum
value of 127. See paragraph 7 on "Serial connection".
5- Slow-down torque (slud torque ) [ 050]
Set the motor torque value during the slow-down phase between 0% and
99%.
6- Opening torque (open torque) [ 70% ]
Set the motor opening torque value between 1% and 99%.
7- Closing torque (cls. torque) [ 70% ]
Set the motor closing torque value between 1% and 99%.
11.2) Logic Menu (logic. )
- TCA ( tca ) [ ON ]
ON
Activates automatic closing
OFF Excludes automatic closing
- 3 Steps (3 step) [ ON ]
ON
Enables 3-step logic. A start impulse has the following effects:
door closed:..............................................................................opens
on opening: .............................stops and enters TCA (if configured)
door open: ............................................................................... closes
on closing: ..........................................stops and reverses movement
after stopping:...........................................................................opens
OFF Disables 3-step logic
INSTALLATION MANUAL
- Opening Impulse lock (Ibl open) [ ON ]
ON
The Start impulse has no effect during the opening phase.
OFF The Start impulse becomes effective during the opening phase.
- Impulse lock TCA (ibl TCA ) [ ON ]
ON
The Start impulse has no effect during the TCA dwell period.
OFF The Start impulse becomes effective during the TCA dwell period.
- Pre alarm (pre-alarM) [ OFF ]
ON
The blinker comes on about 3 seconds before the motor starts.
OFF The blinker comes on at the same time as the motor starts.
- Photocells on opening (photc. open) [ ON ]
ON:
In case of obscuring, this excludes photocell operation on opening.
During the closing phase, it immediately reverses the motion.
OFF: In case of obscuring, the photocells are active both on opening and
on closing. When a photocell is obscured on closing, it reverses the
motion only after the photocell is disengaged.
- SCA Alarm (SCA alarm) [ ON ]
ON:
The SCA contact (terminals 12-13) behaves as follows:
with barrier open: ...........................contact closed (warning light on)
with barrier closed: .......................... contact open (warning light off)
during manoeuvre: ............................. intermittent contact (blinking)
OFF: The SCA contact closes according to the modes set by the Alarm
Time parameter.
- Type of barrier (Fast) [
ON:
Fast barrier mod. MOOVI 30S
OFF: Standard barrier mod MOOVI 30RMM/50RMM
Factory-preset value; in case of maintenance or malfunction, check
that the setting corresponds to the barrier model.
The following functions are not active when the standard barrier is set to (OFF):
- Slow-down
- Torque setting (the barrier always works at maximum torque value).
11.3) Radio Menu (radio)
-
Add (add)
Allows you to add one key of a radio control device to the receiver memory;
after storage it displays a message showing the transmitter number in the
memory location (from 01 to 64).
-
Read (read)
Checks one key of a receiver; if stored it displays a message showing the
receiver number in the memory location (from 01 to 64), and the key number
(T1, T2, T3 or T4).
-
Delete (erase 1)
Removes one single key of a transmitter from the receiver memory; after
deletion it displays a message showing the receiver number in the memory
location (from 01 to 64).
-
Eliminate list (erase 64)
WARNING! Completely removes all memorised radio control devices from
the receiver memory.
11.4) Language Menu (Language)
Allows you to set the language on the display programmer.
5 languages are available:
-
ITALIAN (TA)
-
FRENCH (FRA)
-
GERMAN (DEU)
-
ENGLISH (ENG)
-
SPANISH (ESP)
11.5) Default menu (default)
Restores the preset default values on the control unit.
11.6) Self-diagnosis Menu (selftest)
Allows you to carry out control unit self-diagnosis.
If, at the end of the diagnosis, the answer is OK, it means that the control
unit and connected devices operate correctly.
In case of error, the display indicates the number of the terminal which does
not operate correctly; thus proceed to checking the devices connected to
this, making reference to the following table:
22
Start error
23
Stop error
24
Photocell error
25
Opening limit-switch error
26
Closing limit-switch error
28
Open error
29
Close error
30
Electric edge error
31
Clock error
11.7) Statistics
Having connected the UNIPRO programmer to the control unit, enter the
CONTROL UNIT / STATISTICS menu and scroll the screenful showing the
statistical parameters:
-
Board microprocessor software version.
-
Number of cycles carried out. If motors are replaced, count the number
of manoeuvres carried out up to that time.
ENGLISH
]
MOOVI 30S-30RMM-50RMM Ver. 07 -
19

Publicidad

Tabla de contenido
loading

Tabla de contenido