Descargar Imprimir esta página

Behringer Legendary 2500 Serie Guia De Inicio Rapido página 8

Ocultar thumbs Ver también para Legendary 2500 Serie:

Publicidad

14
DUAL ENVELOPE GENERATOR MODULE 1033
DUAL ENVELOPE GENERATOR MODULE 1033 Controls
(CN) 控制
SUSTAIN LEVEL –
(5)
其峰值之后但在释放之前保
持的电平
或按住手动门控按钮
就保持不变。
GATE DELAY –
从初始门输入开
(1)
3
始将包络周期最多延迟
秒。
FINAL DECAY TIME –
(6)
入信号停止或释放手动门按
SIGNAL LED –
(2)
指示何时出现门
钮之后
控信号。
TRIGGER MODE –
(7)
ATTACK TIME –
(3)
调整包络达到
间选择
其峰值电压的速率。
,
或多重模式
INITIAL DECAY TIME –
调整包络
(4)
信号时使用正触发脉冲重新
从峰值衰减到指定峰值的速
触发包络。
率维持水平。
MANUAL GATE –
(8)
包络周期。
GATE–
控制包络在
连接门信号以控制包
(9)
络周期。
,
只要存在输入信号
TRIG –
(10)
如果还存在门信号
,
该电平
则触发对信封的新攻击。
OUT L –
3.5
(11)
通过
毫米
控制在输
将左信封的正和负控制电压
发送到其他模块。
,
信封掉落的速度。
OUT R –
3.5
(12)
通过
毫米
在单模式之
,
将正确的信封正
负控制电压
,
只有门信号控制包
发送到其他模块。
,
在出现门控
按住以启动
Power Connection
P1
Red Stripe
2
1
10
9
,
200 mm ± 10
TS
电缆
Connect end P1 to the module socket
TS
Connect end P2 to the power supply
电缆
The module comes with the required power cable for connecting to a standard Eurorack power supply system. Follow these
steps to connect power to the module. It is easier to make these connections before the module has been mounted into
a rack case.
1.
Turn the power supply or rack case power off and disconnect the power cable.
2.
Insert the 16-pin connector on the power cable into the socket on the power supply or rack case. The connector has a
tab that will align with the gap in the socket, so it cannot be inserted incorrectly. If the power supply does not have a
keyed socket, be sure to orient pin 1 (-12 V) with the red stripe on the cable.
3.
Insert the 10-pin connector into the socket on the back of the module. The connector has a tab that will align with
the socket for correct orientation.
4.
After both ends of the power cable have been securely attached, you may mount the module in a case and turn on
the power supply.
Installation
The necessary screws are included with the module for mounting in a Eurorack case. Connect the power cable before mounting.
Depending on the rack case, there may be a series of fixed holes spaced 2 HP apart along the length of the case, or a track
that allows individual threaded plates to slide along the length of the case. The free-moving threaded plates allow precise
positioning of the module, but each plate should be positioned in the approximate relation to the mounting holes in your
module before attaching the screws.
Hold the module against the Eurorack rails so that each of the mounting holes are aligned with a threaded rail or threaded
plate. Attach the screws part way to start, which will allow small adjustments to the positioning while you get them all
aligned. After the final position has been established, tighten the screws down.
Quick Start Guide
P2
1
2
HOT USED
15
16
+ 12V
+ 12V
GROUND
GROUND
- 12V
- 12V
15

Publicidad