VESSEL VRO20
3 - SAFETY
The electrical safety of this equipment is only ensured when connected to an electrical system provided with an efficient grounding and a differential circuit breaker
pursuant to law.
- do not allow the reverse osmosis purifying system to be used by children without supervision;
- before carrying out any cleaning or maintenance operation, disconnect the reverse osmosis purifying system from the electricity mains by taking out the plug from
the power outlet;
- in the event of a fault or poor operation, switch off the reverse osmosis purifying system and do not tamper with it. Contact an authorised technician for any
intervention..
The manufacturer cannot be held in any way liable for possible inaccuracies in this instruction manual due to printing or transcription errors.
The manufacturer also reserves the right to bring all changes to the reverse osmosis purifying system, as deemed useful or necessary, without altering its basic
characteristics.
4 - STORAGE
The packaged equipment must be stored in a dry place (without condensate), protected against bad weather. The permitted temperature is 0 - 45°. You should consider
that, even if carefully packaged and protected, the system must be considered and handled as fragile material. On receipt, the packaging must be opened to check the
equipment is intact. If damaged, immediately notify the carrier.
5 - CONDITIONS OF USE AND PERIOD OF USE
Reverse osmosis system - processing essentially consists in an adjustable reduction of TDS (Total Dissolved Solids) in treated water.
Attention:
This equipment requires regular maintenance to guarantee the potability requirements of the treated drinking water and to maintain the improvements
declared by the manufacturer of the reverse osmosis system for household use, to treat drinking water. Equipment for the treatment of drinking water. Input water must
be drinkable according to local law requirements.
Summary table for time of use and maintenance methods
Time of use
Activated carbon filter life
Membrane life
Machine off without electrical supply
For the maintenance method, see the specific chapter.
Time
10 years
Most critical condition: 12 months or
exhaustion
Most critical condition: 2 years or
exhaustion
Over 10 days or time uncontrolled
VESSEL VRO23
Assessment method
This manual
Board signalling
This manual
Ascertain by calendar
Action
Service by manufacturer or disposal
Replacement
Replacement
Intervention to replace membranes and
pre-filter