3 - MAINTENANCE
For all technical and operational issues, please contact the manufacturer's Customer Service (customerservice@atlasfiltri.com).
Installation and maintenance should be carried out to standard by specialist technicians, in compliance with local law requirements. At each maintenance
intervention carried out, strictly fill in the maintenance table at the end of this manual, which should be kept with the system.
Replacement of the internal pre-filter
-
Procedure to replace the cartridge:
- Cut off power by disconnecting the electrical power plug.
- Remove the upper cover.
- Turn the exhausted cartridge counter-clockwise and remove it.
During the operation, it is inevitable that a small amount of water will leak from the pipes.
- Insert the new cartridge and turn it clockwise to the end, until you hear a click, and align the closed lock icon to the arrow on the head.
- Check carefully that there are no water leaks.
Procedure to replace the membranes:
- Cut off power by disconnecting the electrical power plug.
- Dismount the modular vessel assembly, remove the caps using the appropriate vessel key. During this operation, water will inevitably exit from the vessels.
- Insert the new membranes, check if the O-rings are correctly positioned and assemble the caps on the vessels.
- Mount the vessel modular assembly.
- Check carefully that there are no water leaks.
- To re-start the reverse osmosis purifying system, follow the procedure given under: "installation".
- Check that there are no traces of water on the bottom.
CLEANING THE CHECK VALVES AND THE FLOW RESTRICTOR
Proceed as follows:
• Dismount the osmosis modular assembly.
• Dismount the fixing nuts of the output module.
• Remove the output module, remove the check valves, clean or replace them, check for proper functionality. Carefully clean the compartment and reassemble as shown
in the figure (pay attention to the position of the OR and the orientation of components!). Assemble the tie rods, the nuts with thread-locker, tighten them with a torque
screwdriver to 1.8 N/m. Remount the modular vessel assembly.
NON-RETURN VALVE OR OUTWARD
NON-RETURN VALVE OR OUTWARD
Important:
After installation, the machine must be powered on for hygiene reasons (flushing) and for a correct management of the exhausted filter and replace the
pre-filter after periods of disuse longer than 10 days in the absence of electrical power supply.
4 - OUTLET MODULE MAINTENANCE VRO23
Periodically, you should inspect and clean the adjustment device of the pressure. To dismantle it, simply remove the orange plug and remove the module, proceed as
follows
• Dismantle and clean the check valve 4H with water and air. When re-assembling it, position the stop 4I correctly.
• Remove the screws 4A
• Carefully examine the pin 4F and the membrane 4G, wash carefully with air and water, replace when necessary
• If present, replace the sensor TDS 4J, having reassembled it and started the system, recalibrate reading
• Wash the body carefully with water and air, especially the compartment with the pin and internal decanters. Do NOT scratch with pointed objects or abrasive materials!
• Reassemble the components
14