FOR INSTALLATION TECHNICIAN ONLY
Atlas Filtri declines any responsibility resulting from the incorrect use of this section
1 - INSTALLATION
Installation and maintenance should be carried out to standard by specialist technicians.
When the installation is completed, strictly fill in the installation certificate at the end of this manual, which should be kept with the system.
The reverse osmosis purifying system was designed for installation in a household environment, not outdoors, in a hygienically suitable location, protected from frost.
It must also be connected to standard to the electricity mains and the drinking water mains, in compliance with the technical characteristics outlined in chapter 2.
• For a perfect preservation, the membranes are kept in a bacteriostatic liquid. Therefore, do not use the first water produced by a new system, or on which
the osmotic membrane was replaced, but let it flow for 2 cycles of approx. 10 minutes, with 5-minute stop intervals.
• A pre-filter must be used for well, cistern or surface water.
• Installations, repairs, interventions or changes must be carried out by authorised staff.
Before proceeding with the installation, check if there is enough space to:
• Comfortably install the water connections;
• Easily remove spare parts;
• Carry out maintenance.
Check if there is a power outlet in the immediate vicinity of the machine.
Water and electricity connection:
Connect as indicated
MACHINE CONNECTION
PIPE
In (water supply)
John Guest 8mm black pipe
OUT, grey clip (permeate)
John Guest 1/4" white pipe
DRAIN, red clip (drain)
John Guest 1/4" red pipe
Start-up:
• Open the water supply slowly, making sure there is no leakage.
• Connect the power supply cable to NEXT.
• Switch-on the machine using the switch on the back
• Open the tap and let water flow to bleed the air.
ATTENTION: Do not operate the machine without having opened the water supply first. The pump can suffer irreparable damage if run dry.
ATTENTION: After operation, let the water flow for 2 cycles of approx. 10 minutes, with 5-minute stop intervals.
Carefully fill in the installation certificate and the maintenance table. Everything must be kept with the system. If the documentation is not filled in properly, the
manufacturer cannot be held in any way liable for the quality of the water treated and for the integrity of the system. Check and, as necessary, adjust pressure and TDS
(Total Dissolved Solids) (see dedicated section).
Anti-flooding
The machine is equipped with an anti-flooding system, which can detect leaks in the machine and will immediately stop water delivery. The system cannot detect and
block flooding from leaks outside the machine. If necessary, install management and control devices for external flooding.
The manufacturer cannot be held liable for any flood damage caused by leaking components outside the machine.
2 - SPARE PARTS AND PRE-FILTRATION
For maintenance, use only spare parts supplied or approved by the manufacturer.
The machine requires carbon filter pre-filtration, which is not optional, use only materials supplied or approved by the manufacturer. Not installing pre-filtration or use
of unapproved components will cancel the warranty.
SYSTEM CONNECTION
Cold water system for household use
Delivery tap
Drainage collar
REPLACEMENT
RE5395400 - PRE-FILTER CB QF NEXT
RE5395402 - 2012-220 GDP / MEMBRANE NEXT 50 - 100
RE5395403 - 2312-330 GPD / MEMBRANE NEXT 130
ON / OFF
SWITCH
Reverse osmosis system
Model year: 2023
Model: NEXT
Power supply: 220V-50HZ 0.55 A
Water supply: max 5 Bar