Descargar Imprimir esta página

Kohler K-5548-K1-TT Guía De Instalación Y Cuidado página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

5" (127 mm)
From Ceiling
Ø 7/16"
(11 mm)
Apply 100%
silicone sealant.
Cable Tie
4. Install the Temperature Sensor
IMPORTANT! Do not locate the temperature sensor directly above
the steam head. Locate the temperature sensor on the wall opposite
the steam head.
IMPORTANT! Make a drip loop in the temperature sensor wire to
prevent moisture from following the wire to the steam generator.
Make sure that the power is turned off at the main breaker panel
before proceeding.
Locate the temperature sensor on the wall 5" (127 mm) down
from the ceiling, on the wall opposite the steam head.
Drill a 7/16" hole at the selected location.
IMPORTANT! Do not pinch, nail, wedge, or use undue force when
handling the sensor wire. Any damage may result in temperature
sensor failure.
Insert the temperature sensor wire through the drilled hole.
Route the wire behind the wall to the steam generator location.
1235393-2-E
Apply 100% silicone
sealant.
Temperature
Sensor
Back View
Ferrite
Drip Loop
10
Kohler Co.

Publicidad

loading

Este manual también es adecuado para: