CAUTION: Risk of unsafe operation. Compressed air from the
unit may contain wa ter condensation and oil mist. Do not spray
un fil tered air at an item that could be damaged by moisture. Some
air op er ated tools or de vic es may require filtered air. Read the
in struc tions for the air tool or device.
3. Adjust regulator (F) to desired setting. See regulator under
Features.
Shut-down (Fig. 1)
1. Move Auto/Off switch (L) to the OFF position. note: If finished
using compressor, follow Steps 2 - 6.
2. Pull the regulator knob (F) out and turn counterclockwise until fully
closed. Ensure regulated pressure gauge reads 0 psi. Push knob
in to lock in place.
3. Remove hose and accessory.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand
when installing or disconnecting to prevent hose whip.
4. Drain the air tank, see Draining Air tank under Maintenance.
Ensure air tank pressure gauge reads 0 psi.
WARNING: Risk of bursting. Drain air tank daily. Water will
condense in air tank. If not drained, water will corrode and weaken
the air tank causing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing
area.
MAINTENANCE
The following procedures must be followed when maintenance or
service is performed on the air compressor.
1. Ensure Auto/Off switch is in the OFF position.
2. Remove air compressor plug from outlet.
3. Drain air tank.
4. Allow air compressor to cool down before starting service.
note: All compressed air systems contain maintenance parts (e.g.,
oil, filters, separators) that are periodically replaced. These used parts
may contain substances that are regulated and must be disposed of in
accordance with local, state, and federal laws and regulations.
note: Take note of the positions and locations of parts during
disassembly to make reassembly easier.
note: Any service operations not included in this section should
be performed by a D
WALT factory service center or a D
e
authorized service center.
Maintenance Chart
Procedure
Check safety valve
Inspect air filter
Drain air tank
Check for unusual noise/vibration
Check for air leaks
Clean compressor exterior
Remove tank from service
1 To check for air leaks apply a solution of soapy water around joints.
While compressor is pumping to pressure and after pressure cuts
out, look for air bubbles to form.
2 - For more information, call 1-800-4-D
13
WALT
e
Daily
Weekly
see tank
warning
label
X
X
X
X
X
1
X
X
2
WALT (1-800-433-9258)