Spacer lock
23
Flap suction hose port on the filter ring
24
Floor nozzle holder
25
Suction hose port on the dirt receptacle
26
Chassis
27
Symbols on the device
The device is suitable for vacuuming dusts
up to dust class H.
WARNING: This device contains dusts that
are harmful to your health. Emptying and
maintenance, including removal of the dust
bag, may only be performed by appropri-
ately trained personnel wearing suitable
personal protective equipment. Do not
switch on until the entire filter system has
been installed and the volume flow control
functionality has been checked.
The device is suitable for vacuuming com-
bustible dusts, installation outside zone 22.
WARNING: This device must not be placed
in any zone 22. If a zone 22 is present, an
EX-device must be used.
WARNING: Risk of crushing
Warning against hand injuries
The maximum vacuum value in relation to
the hose cross-section is specified on the
label. The actual value can be read on the
24
pressure gauge. For the values applicable
to this device, see chapter Reading the
minimum volumetric flow. If this value is not
reached, the filter must be cleaned (see
chapter Dedusting the main filter) or re-
placed (see chapter Replacing the main fil-
ter). The various different hose cross-
sections allow adaptation to the various dif-
ferent connection cross-sections of the ac-
cessories.
Dust bag
(Order no. 9.989-606.0)
Safety filter bag
(Order no. 6.904-420.0)
Main filter
(Order no. 9.990-493.0)
H14 filter
(Order no. 9.993-006.0)
Initial startup
WARNING
Potential equalisation line not connect-
ed correctly
Electric shock
Every time before use, check whether the
equipotential bonding conductor (earthing
conductors) are connected.
WARNING
Danger from dust that is harmful to your
health
Respiratory sicknesses through inhalation
of dust.
Do not vacuum without correctly installed
filter elements, otherwise a danger to
health from increased fine dust emission is
present.
ATTENTION
Missing filter element
Damage to the suction motor
Do not vacuum without a filter element.
1. Bring the device into the working posi-
tion.
2. Secure the device with the parking
brakes.
3. Ensure that the suction head is fitted
correctly.
English