- USING YOUR CEILING FAN
REMOTE CONTROL
1. Open the battery compartment cover by removing the securing screw and insert 2 x AAA battery. Note the
correct battery polarity (+/-) when inserting the battery, and then replace the cover and secure with the
screw.
2. Test the remote by pressing and hold any button. A blue LED will be lit up at the top of the remote to
indicate that there is power to the remote and it is ready for use to control the fan.
3. Follow the guide below to operate the fan and learn the functions.
The remote has memory function. If the fan or light is turned off by the isolating switch over 7 seconds, the
next time to turn on the fan or light will be on last setting.
REPAIRING THE FAN RECEIVER & REMOTE PAIRING
NOTE: The pairing of the remote and receiver has been done at the factory.
When the ceiling fan is installed, pairing the fan receiver and remote is NOT required.
Should the remote and receiver lose control after installation or during use, the pairing of the remote and the
receiver must be repaired. Below are the operating symptoms and method to repair the pairing of the DC
ceiling fan remote and receiver.
Issues:
Loss of control - Fan is only running at high speed after installation.
Loss of control - No reverse function after installation
Loss of control - Remote cannot communicate with the receiver.
Solution:
Switch off the main power of ceiling fan.
Switch on the main power of the ceiling fan. Press and hold the
seconds within 30 seconds after switching on. There will be a long sound 'beep' from the receiver to
indicate that the paring process is successful.
Turn on and select the different speed of the ceiling fan to check the operation of the fan.