Operating modes and configuration
7.5.1
Heating or cooling
You can use your floor heating system
to heat rooms during winter or to cool
rooms during summer.
• Select "HEAT" for heating and
"COOL" for cooling in the menu
item "type" by turning the control
wheel (E) and confirm by pressing
the control wheel briefly.
7.5.2
Heating profile numbers
You can select between the following 6
pre-configured profiles.
• Select the number of the required
profile in the menu item "Pr.nr." by
turning the control wheel (E) and
confirm by pressing the control
wheel briefly.
If the selected profile is a heating
profile, the room is heated as soon
as the temperature falls below the
defined value. If the selected pro-
file is a cooling profile, the room is
cooled as soon as the tempera-
ture increases the defined value.
After switching from "heating" to
"cooling" in the menu, the profiles
are changed from profile 1 to 4,
profile 2 to 5 and from profile 3 to
6 automatically.
Profile 1
Pre-configured heating via radiator
thermostat
Monday to Friday
00:00 - 06:00
06:00 - 09:00
09:00 - 17:00
17:00 - 22:00
22:00 - 23:59
Saturday to Sunday
00:00 - 06:00
06:00 - 22:00
22:00 - 23:59
Profile 2
Pre-configured heating via floor hea-
ting
Monday to Friday
00:00 - 05:00
05:00 - 08:00
08:00 - 15:00
15:00 - 22:00
22:00 - 23:59
Saturday to Sunday
00:00 - 06:00
06:00 - 23:00
23:00 - 23:59
Temp.
17,0 °C
21,0 °C
17,0 °C
21,0 °C
17,0 °C
Temp.
17,0 °C
21,0 °C
17,0 °C
Temp.
19,0 °C
21,0 °C
19,0 °C
21,0 °C
19,0 °C
Temp.
19,0 °C
21,0 °C
19,0 °C
36