2. Instructions For Use; Maintenance Instructions; 1. Overhauling - Technoflex VAF-38LT Manual De Instrucciones

Ocultar thumbs Ver también para VAF-38LT:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Before starting, the transmission must be checked, paying special attention for the started of plug,
electric cable, switch box, and functioning of this. Before any rib, rupture or damage it must be repaired,
to avoid subsequently faults.
Under no circumstance, make any reparation or change lof pieces with the hose plug into the
connection plug of the converter.
Once it has been revised, check that the transmission's switch is in position "0", connect the plug up to
the connection base of the converter and may be started subsequently the transmission switch may be
moved to the position "I".
NOT use converter's plug for starting up or stop it, always must be used with the corresponding switch.
Under ANY circumstances, have the arrange switch of the needle in position "I" (starting position) before
that the converter has been started, it means that the first the converter must be started and then the
vibrating needle, because it starts on load and overcoat in Single-Phase models may produce a fault in
the motor of the converter.
With temperatures below 3° C., the vibrator may pres ent difficulties to start after a long period stopped,
this is due to the solidifying of the grease bearings and of the cable, it must start letting the vibrator run
light long enough for normal vibration to be achieved.

2.-2. Instructions for Use

Be careful to avoid that the electrical cable works forming Knots or interlacing, also with very closed
bend, this produces premature and unnecessary wearing of the flexible cable, causing even their
immediate breakage.
Avoid the electrical cable being near heat sources, or that it slips to where there are objects with sharp
edges, it must also be protected from heavy machines and other objects which may cause its
deterioration.
Do not allow personnel not capable to make use of the vibrator or manipulate the electric parts.
The concrete must vibrate in horizontal layers, the needle must NEVER be used to move the concrete
laterally.
The vibrator must NEVER be stopped while it is introduced into the concrete, to stop it must be taken
out of it first.
3

MAINTENANCE INSTRUCTIONS

3.-1. Overhauling

Depending on conditions of use and at the maximum every year, must be carried out a complete
overhauling of the converter. The state of the plug, electric cable, needles bearings, wear of exterior
tubs and the ends must be check.
If the loose bearings, heats up or make too much noise must be replaced and always remember
ORIGINAL SPARE PARTS MUST BE USED.
The greasing of the bearing must be done with grease STABURAGS NBU 4 from the firm KLÜBER
LUBRICATION or any other equivalent one.
Remember, for safety reasons do not forget to disconnect converter the transmissions when some kind
of operation or part substitution is made.