5
42
Operation pattern setting screen will appear.
Press the
button to move the cursor to the desired
F1
pattern number.
Move the cursor to the time, On/Off, or temperature
with the
button.
F2
Change the settings with the
•
Time: settable in 5-minute increments
* Press and hold the button to rapidly advance the
numbers.
•
On/Off/Auto: Selectable settings depend on the model of
connected indoor unit. (When an Auto pattern is executed,
the system will operate in the Auto (dual set point) mode.)
•
Temperature: The settable temperature range depends on
the connected indoor units. (1ºC/1ºF increments)
When the Auto (dual set point) mode is selected, two
preset temperatures can be set. If an operation pattern
with a single preset temperature setting is executed during
the Auto (dual set point) mode, its setting will be used as
the cooling temperature setting in the Cool mode.
Press the
SELECT/HOLD
A confirmation screen will appear.
Navigating through the screens
• To go back to the setting change/day of the week selection
screen .............................................
• To go back to the Main menu .........
• To return to the previous screen .....
will appear on the Main display in the Full mode
when the weekly timer setting for the current day
exists.
The icon will not appear while the On/Off timer is
enabled or the system is under centralized control
(Timer operation from local remote controller is
prohibited), or while the HOLD function is enabled.
or
button.
F3
F4
button to save the settings.
button
SELECT/HOLD
button
MENU
button
RETURN