INSTALLATION
Refer to FIGURE 2
1. Nail mounting bracket to joist or stud. Use gauge on bracket to
locate it for 1/2" or 3/4" drywall.
Refer to FIGURE 3
2. Snap fan housing onto bracket.
Refer to FIGURE 4
3. Remove the knockout plate from fan. Break out either top or
rear electrical access hole. Insert a screwdriver into slot in knock-
out and bend back and forth to break tabs.
NOTE: Turn off power and lock out service panel before installing
electrical wiring.
Refer to FIGURE 5
4. Secure power cable to knockout plate with proper connector
for type of cable being used. Allow 6" of cable to extend beyond
knockout plate. Connect ground wire to green ground screw on
knockout plate.
FIGURE 4