Line Regulation:
Load Regulation:
Ripple & Noise
(20MHz bandwidth):
Transient Load
Response:
Voltage Programming
Speed:
Range and Setting
60V 7A
20V 20A
Temperature Coefficient:
Status Indication:
METER SPECIFICATIONS
Meter Types:
Meter Resolutions:
Meter Accuracies:
ADDITIONAL SPECIFICATIONS
Independent Mode:
VoltageTracking Mode:
(V
)
TRACK
Tracking Accuracy:
Synchronous On/Off:
Change in output for a 10% line change:
Constant voltage: <0.01% of maximum output
Constant current: <0.01% of maximum output
Change in output for any load change within PowerFlex envelope, remote
sense connected:
Constant voltage: <0.01% of maximum output
Constant current: <0.05% of maximum output
5mVrms max; typically <3mVrms, <15mV pk-pk, at maximum load, CV mode.
<250us to within 50mV of set level for a 5% to 95% load change.
Maximum time required for output to settle within 1% of its total excursion
(for resistive load). Excludes command processing time.
90% Load
Up
8ms
Up
8ms
Typically <100ppm/°C
Output ON lamp.
Constant voltage mode lamp.
Constant current mode lamp.
Unregulated (power limit) lamp
Remote lamp
LAN lamp
Trip message on display.
Dual 4 digit meters with 10mm (0.39") LEDs. Reading rate 4 Hz.
10mV, 10mA
Voltage 0.1% of reading ± 2 digits
Current 0.3% of reading ± 2 digits
Each output is fully independent and isolated. Operation is equivalent to two
single power supplies.
With V
selected the voltage controls of Output 1 (the Master) set an
TRACK
identical voltage on Output 2. The outputs remain isolated and the current
controls remain independent.
Locking the Master (S-Lock) also locks the voltage of Output 2.
Slave voltage = Master voltage ± (0.1% of Master voltage ± 20mV)
In addition to the independent DC On/Off controls for each output, the outputs
can be turned on or off simultaneously using the Synchronous On/Off key. This
key operates in all modes.
No Load
8ms
Down
8ms
Down
90% Load
No Load
80ms
1.5s
10ms
1.2s
3