NOTICE
Do not use check valves or foot valves; valves reduce rate of flow and performance of the pump.
Nozzle Boot Installation
Install the nozzle boot using the supplied attaching bolt. Note that the bolt is
inserted through the hole closest to the nozzle opening, and the boot is then
positioned so the peg on the pump mounting surface inserts in the top second
hole of the boot. This allows for correct alignment of the nozzle when inserted
into the boot.
Pump Foot Installation
The mounting foot is bolted to the bottom of the pump using
the four supplied socket head cap screws. Mount the foot
with the bolt flanges inboard of the mounts on the pump as
illustrated. Torque to 50 in lb. with 4 mm hex key.
fillrite.com
NX25-DDC SERIES DC FUEL TRANSFER PUMPS
INSTALLATION AND OPERATION MANUAL
Mounting peg
Mounting bolt
5