Specific Precautions/Optical Scan Laser
The Optical Scan Laser is a class 3R laser designed to measure
tread depth . The laser is not a field serviceable part . No
maintenance is to be performed on the laser .
The non-visible laser beams are on when the Hunter logo is
illuminated .
The laser beam is terminated when a vehicle passes or when it
reaches the other tower .
LASER LIGHT
AVOID DIRECT EYE EXPOSURE
CLASS 3R LASER PRODUCT
638/658nm <7mW CW
EN/IEC 60825-1 2014 (2007 USA)
RAYON LASER
ÉVITER TOUTE EXPOSITION DIRECTE
This laser product is designated as Class 3R during all procedures
AVEC LES YEUX
of operation .
PRODUIT LASER DE CLASSE 3R
Wavelength: 638/658nm
638/658nm <7mW CW
Laser power for classification: <7 mW
This product is properly classified at 7mW due to
the laser's "extended source" .
Complies with FDA performance standards for
laser products except for deviations pursuant
Emission type: CW
to Laser Notice No. 50, dated June 24, 2007.
Beam diameter: <3 mm at aperture
Divergence: <1 mRad
Conforme aux normes de performance de la
FDA pour les produits laser sauf les déviations
Fan angle: 60°
conformément à l'avis de laser no. 50 du 24
ATTENTION: It is the responsibility of management
and supervisors to:
- Issue appropriate instructions and training materials
on laser hazards and the control of the hazards to all personnel
working with lasers in their area .
- Assure that the facility complies with the standards
established by the International Electrotechnical Commission,
60825-1 standard; the Laser Institue of America, ANSI Z136
standard; as well as all local standard requirements .
Corporate Information:
Hunter Engineering Company
11250 Hunter Drive
Bridgeton, MO 63044 U .S .A .
Phone: 314-731-3020 / Fax: 314-731-1776
Web: www .hunter .com
Specific Precautions/Power Source
International Regions
The Quick Tread Edge is intended to operate from a power source
that will apply 115230 VAC (nominal) 50/60 Hz, 15 Amp, single-
phase. Your Hunter service representative will determine the proper
requirements for your location .
EQUIPMENT SERVICE:
This equipment contains no user serviceable parts . All repairs must
be referred to a qualified Hunter Service Representative .
English
Image 7.
Juin, 2007.
128-1795-2-18
Equipment Specifications
SITE SPECIFICATIONS
Power Requirements
Air Supply Req . (SI Units)
Substructure
Specifications
Internet Connection
PRODUCT SPECIFICATIONS
Test Entry Speed
Minimum Required Light
Condition
Altitude:
SHIPPING WEIGHT
Quick Check Cabinet
Quick Tread Edge
Flush
TM
ATMOSPHERIC
Temperature
Relative Humidity
* Amperage shown is minimal circuit rating .
Ɨ Isolated ground recommended.
Image 8.
These standards enable use of the product in garages and
hazardous locations (Class I, Division 2) . The product can be used
in a location classified as Class I, Division 1 (recessed in a pit) by
reclassifying the pit to the Division 2 by use of ventilation per NEC .
Environmental Considerations
Environmental Considerations
Normal rainwater will not harm the sensors or plates . The system
must not be installed outdoors or in areas exposed to rain or
potential flooding . Hosing down the system is permissible, however
installation in areas of standing water or flooding is prohibited .
Do not pressure wash the tread depth sensors under any
circumstances .
Certain shops may need to drive vehicles over the
sensors when they are powered off, such as a dealership
porter moving vehicles around after hours . This can
result in water and debris falling onto the sensor
windows and drying, since the air knives will not operate . It is
recommended in these situations to inform the customer to either
leave the system powered on at all times, or manually clean the
windows if necessary, before powering on the system every day .
115/230V, 15 amp*, 50/60 Hz, 1
ph †
6 .2-10 .3 bar (90-150 PSI)
Refer to Form 7615-T
20 Mbps (Ethernet cable required)
3-13 kph (2 to 8 mph)
400 Lux
Up to 3048 m (10000 ft . )
WU572: 179 kg, WU592: 73 kg
771 kg
0°C to +50°C
Up to 95% Non-condensing