Method 2 - Power Supply Cord
IMPORTANT:
•
The power cord and connections must comply with the National
Electrical Code, Section 422 and/or local codes and ordinances.
Recommended cord length is 54" min. and 64" max.
•
A mating 3 prong, ground-type wall receptacle is required in a cabinet
next to the dishwasher opening.
•
A power cord kit part #BK500 is available for purchase from an
authorized parts dealer.
1/2
Drill a 1
1.
Optional locations are shown in the following graphic.
2.
Smooth edges of hole for power cord.
Wood Cabinet - Sand edges of hole until smooth.
Metal Cabinet - Cover edges of hole with grommet (not provided).
3.
Attach power cord to dishwasher before moving it into the opening.
See "Connect Power Supply" section for proper installation technique.
WARNING
18
PREPARE TO CONNECT WATER LINE
NOTE: Routing the water line through the left side of cabinet opening will
make water connection easier.
1/2
Drill a
1.
optional locations are shown in the following graphic.
Measure to determine the overall length of copper tubing required for
2.
the water line.
IMPORTANT: Slowly feed copper tubing through hole in cabinet.
Copper tubing bends and kinks easily, so handle the tubing gently.
" (3.8 cm) hole in the cabinet rear or side. Preferred and
b
a
Electrical Shock Hazard
•
Plug into a grounded 3 prong outlet.
•
Do not remove the ground prong from the power cord
plug.
•
Do not use an adapter.
•
Do not use an extension cord.
•
Failure to do so can result in death, fire or electrical
shock.
" (1.3 cm) hole in the cabinet side, rear or floor. Preferred and
a
Preferred Locations
b
Optional Locations