Descargar Imprimir esta página

Fulgor Milano F4GK30S1 Instrucciones De Installación página 14

Placa de cocción de gas
Ocultar thumbs Ver también para F4GK30S1:

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
Gas Connection
Thread the appliances pressure regulator with 1/2"
male end connection both supplied with this appliance.
Make the gas connection to the inlet of the pressure
regulator with 1/2" male pipe threads.
Join the pressure regulator to the entrance threads
of the Gas Manifold with gasket supplied with this
appliance. The regulator is marked with a directional
arrow indicating correct direction of gas flow. Ensure the
appliance regulator is installed with the arrow pointing
toward the gas manifold entrance and make sure the top
of the regulator is facing towards the cabinet front, easily
accessible through the cabinet doors.
• Connect a manual shut-off valve to the gas supply in an
accessible location for turning on or shutting off gas to
the appliance.
• Install a coupling between the regulator and the shutoff
valve to complete the connection.
• Assure all pipe joint connections are gas tight.
• Check alignment of valves after connecting the cooktop
to the gas supply to be sure the manifold pipe has not
been moved.
• A misalignment could cause the valve knob stem to rub
on the control panel, resulting in a gas leak at the valve.
If an oven is to be installed below this appliance connect gas
supply line as shown in figure consider the below cabinet
clearance.
10
ILLUSTRATIVE GAS SUPPLY PIPING
(NO OTHER APPLIANCE BELOW
COOKTOP)
BURNER BOX
(REAR OF APPLIANCE)
GASKET
FLARE UNION
ADAPTOR
APPLIANCE
PRESSURE
REGULATOR
ALL PIPE JOINTS
1/2" N.P .T.
MANIFOLD
SHUTOFF
VALVES
GAS

Publicidad

loading