DESCRIPTION OF THE APPARATUS (Fig. 1)
1.- Top.
2.- Water tank.
3.- Humidifier body.
4.- Water level indicator.
5.- Digital controls and screen.
6.- Steerable atomization diffuser.
7.- Steam generation pipe.
8.- Mains lead.
9.- Water level sensor.
10.- Transducer.
DESCRIPTION OF THE CONTROL PANEL(Fig. 2)
1.- Continuous operation symbol.
2.- Humidity selector.
3.- Output flow selector.
4.- ON/OFF button.
5.- Programming symbol.
6.- Room Relative Humidity symbol.
7.- Output flow indicator.
8.- Tank empty symbol.
PROGRAMMING AND FUNCTIONS
1. Fill the water tank and place it back in its original position. (Clean water with no fragrances and a tem-
perature of less than 40º C. To avoid lime scale problems it is recommended to use distilled water).
2. Connect the plug to the mains. (Check that the data on the name plate coincides with the mains voltage).
3. Press the ON/OFF button to start the unit.
4. The programming range for R.H. is from 40% - 85%.
The appliance can also be programmed to work continuously CO% (
With the humidity selector (+/-), program the % of Relative Humidity required in the room. As a
starting point, we recommend a value between 50% and 60%; at these values the human body is
"comfortable".
The programming symbol (PRG) will light up to indicate that you are programming the appliance.
The numeric display will flash.
5. Once the required R.H. has been entered, after 3 seconds, the Room Relative Humidity indicator
(RH%) will light up. If the R.H. in the room is lower than the programmed value, the appliance
will start working, when the values are the same, the appliance will automatically stop generating
humidity. Via an electronic sensor, the appliance will keep the room at the R.H. programmed by
the user with a precision of ±5%.
NB: If the R.H. of the room is lower than 30% LO % will appear on the screen. If the R.H. in the
room is higher than 90% HI % will appear on the screen.