ROUBLESHOOTING
Ice and Water
PROBLEM
POSSIBLE CAUSES
• Ice maker arm is on OFF position.
Ice maker is not
producing ice
• Household water supply is not
• Copper tubing has kinks.
• Water pressure is too low.
• Check freezer temperature.
• Exceeded normal operating
Temp Alarm Light
is flashing
• Control has been set to Sabbath
All lights on
dispenser and
interior lights are
off and appliance
is still running
• Alarm mode has been disabled.
Door alarm set, no
alarm sounded
• Temperature display has been set to
Temperatures in
display look too low
All manuals and user guides at all-guides.com
reaching water valve.
temperatures.
Mode.
Celsius rather than Fahrenheit.
WHAT TO DO
• Confirm ice maker arm is down. See Automatic Ice
Maker, page 15.
• See Connecting the Water Supply pages 7-8.
• Turn off water supply and remove kinks. If kinks
cannot be removed, replace tubing.
• Water pressure must be between 35 to 100 pounds
per square inch to function properly. A minimum
pressure of 35 pounds per square inch is
recommended for refigerators with water filters.
• See Temperature Controls, pages 9-11. Freezer
temperature should be between 0° to 2° F (-18° to
-17° C) to produce ice.
• See Temp Alarm, pages 10-11.
• See, Sabbath Mode, page 11.
• To activate audible alarms, refer to pages 10-11.
• See Temperature display on page 11.