EHP System III
iii
Installation procedures
Electric installation
THE INSTALLATION SHALL BE CARRIED OUT ONLY
BY QUALIFIED PERSONNEL AND WITHIN THE SCOPE
OF THE INSTRUCTIONS PROVIDED IN THIS MANUAL.
Check on the plate of the machine that the electrical
specifi cations of the power source are the same as the
machine.
The machine, depending on the ordered version, may
require:
115VAC +/-10% 1ph 60Hz 12A
1 phase motor
or
230VAC +/-10% 1ph 50/60Hz 16A
1 phase motor.
Electrical specifi cations are clearly marked on a label at
the end of the electric cable.
The user must ensure that the electrical system that the
115V machine is connected to is fi tted with 30 A delayed
fuses.
20 A (25 A for Japan); in case of 230V machine with
INVERTER, or alternatively, an equivalent automatic
magneto-thermic switch.
Before connecting the machine to the power source check
that the power supply has an effi cient earthing system.
Connect the electric cable of the machine with an
approved plug.
Note:
The outlet installation must be verifi ed by a
licensed electrician before connecting the tire
changer.
Note:
The yellow/green wire in the cable is the earth
wire. Never connect the earth wire to a live
terminal.
Check that the power supply has an automatic circuit
breaker with a diff erential circuit rated at 30 mA.
WARNING: IF INVERTERS ARE PRESENT, ONLY
USE TYPE B RESIDUAL CURRENT OPERATED
CIRCUIT BREAKERS.
The electric motor operates in a wide voltage range (plus
or minus 10%) and frequency range (60 Hz) and has a
class of insulation suitable for hot and moist climates.
36
- EN