Descargar Imprimir esta página

Mitsubishi Electric Mr.SLIM PEAD-RP140JAQ Manual De Instrucciones página 6

Ocultar thumbs Ver también para Mr.SLIM PEAD-RP140JAQ:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50
5. Operation
<To Stop Operation>
■ Press the ON/OFF button 1 again.
• The ON lamp 1 and the display area go dark.
Note:
Even if you press the ON/OFF button immediately after shutting down the op-
eration is progress, the air conditioner will not start for about three minutes.
This is to prevent the internal components from being damaged.
5.2. Mode select
■ Press the operation mode (
tion mode 2.
s
Cooling mode
Drying mode
Fan mode
Heating mode
Automatic (cooling/heating) mode
Ventillation mode
Only indicated on the following condition
Wired remote controller used
LOSSNAY connected
Information for multi system air conditioner (Outdoor
unit: MXZ series)
s s s s s Multi system air conditioner (Outdoor unit: MXZ series) can con-
nect two or more indoor units with one outdoor unit. According to
the capacity, two or more units can operate simultaneously.
• When you try to operate two or more indoor units with one outdoor unit
simultaneously, one for the cooling and the other for heating, the opera-
tion mode of the indoor unit that operates earlier is selected. The other
indoor units that will start the operation later cannot operate, indicating
an operation state in flashing.
In this case, please set all the indoor units to the same operation mode.
• There might be a case that the indoor unit, which is operating in
(AUTO) mode. Cannot change over to the operating mode (COOL ↔
HEAT) and becomes a state of standby.
• When indoor unit starts the operation while the defrosting of outdoor
unit is being done, it takes a few minutes (max. about 15 minutes) to
blow out the warm air.
• In the heating operation, though indoor unit that does not operate may
get warm or the sound of refrigerant flowing may be heard, they are not
malfunction. The reason is that the refrigerant continuously flows into it.
Automatic operation
■ According to a set temperature, cooling operation starts if the room tem-
perature is too hot and heating operation starts if the room temperature
is too cold.
■ During automatic operation, if the room temperature changes and re-
mains 2 °C or more above the set temperature for 15 minutes, the air
conditioner switches to cooling mode. In the same way, if the room tem-
perature remains 2 °C or more below the set temperature for 15 min-
utes, the air conditioner switches to heating mode.
Cooling mode
15 minutes (switches
from cooling to heating )
6
) button 2 and select the opera-
15 minutes (switches
from heating to cooling)
Set temperature +2°C
Set temperature
Set temperature -2°C
■ Because the room temperature is automatically adjusted in order to
maintain a fixed effective temperature, cooling operation is performed a
few degrees warmer and heating operation is performed a few degrees
cooler than the set room temperature once the temperature is reached
(automatic energy-saving operation).
5.3. Temperature setting
s s s s s To decrease the room temperature:
Press
button 3 to set the desired temperature.
The selected temperature is displayed 3.
• Each time you press the button, the temperature value decreases by 1 °C.
s s s s s To increase the room temperature:
button 3 to set the desired temperature.
Press
The selected temperature is displayed 3.
• Each time you press the button, the temperature value decreases by 1 °C.
• Available temperature ranges are as follows:
Cooling/Drying:
19 - 30 °C
Heating:
17 - 28 °C
Automatic:
19 - 28 °C
• The display flashes either 8 °C - 39 °C to inform you if the room tem-
perature is lower or higher than the displayed temperature.
5.4. Fan speed setting
■ Press 5
button to select a desired fan speed.
• Each time you press the button, available options change with the
display 5 on the remote controller, as shown below.
Remote controller display
Fan speed
Low
Medium
(
)
(
3-stage
High
Auto
)
(
)

Publicidad

loading