5. Operation
The display and the fan speed of the unit will differ in the following situa-
tions:
• When STAND BY and DEFROST are displayed.
• Just after the heating mode (while waiting to change to another mode).
• When the temperature of the room is higher than the temperature set-
ting of the unit operating in the heating mode.
• In the dry operation, the indoor fan automatically turns to low-speed
operation. Switching of fan speed is impossible.
• When the temperature of the heat exchanger is low in the heating mode
(e.g., immediately after heating operation starts).
Note:
● In the following cases, the actual fan speed generated by the unit will differ
from the speed shown the remote controller display.
1. While the display is showing "STAND BY" or "DEFROST".
2. When the temperature of the heat exchanger is low in the heating mode.
(e.g. immediately after heating operation starts)
3. In HEAT mode, when room temperature is higher than the temperature
setting.
4. When the unit is in DRY mode.
6. Timer
6.1. For Wired Remote-controller (option)
You can use Function Selection of remote controller to select which of
three types of timer to use: 1 Weekly timer, 2 Simple timer, or 3 Auto Off
timer.
6.1.1. Weekly Timer
■ The weekly timer can be used to set up to eight operations for each day
of the week.
• Each operation may consist of any of the following: ON/OFF time
together with a temperature setting, or ON/OFF time only, or tempera-
ture setting only.
• When the current time reaches a time set at this timer, the air
conditioner carries out the action set by the timer.
■ Time setting resolution for this timer is 1 minute.
Note:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same time.
*2. The weekly timer will not operate when any of the following conditions is in
effect.
The timer feature is off; the system is in an malfunction state; a test run is
in progress; the remote controller is undergoing self-check or remote con-
troller check; the user is in the process of setting a function; the user is in
the process of setting the timer; the user is in the process of setting the
current day of the week or time; the system is under central control. (Spe-
cifically, the system will not carry out operations (unit on, unit off, or tem-
perature setting) that are prohibited during these conditions.)
Operation No.
4
2
3
TEMP.
MENU
ON/OFF
BACK
MONITOR/SET
DAY
PAR-21MAA
CLOCK
2
A
<How to Set the Weekly Timer>
1. Be sure that you are at a standard control screen, and that the weekly
timer indicator 1 is shown in the display.
Day Setting
SUN
ON
1
˚C
WEEKLY
3
ON/OFF
1
B
FILTER
4
CHECK
TEST
0
OPERATION
CLEAR
9
78
5.5. Ventillation
s s s s s For LOSSNAY combination
5.5.1. For Wired Remote-controller
● To run the ventilator together with the indoor unit:
■ Press the ON/OFF button 1.
• The Vent indication appears on the screen (at 8). The ventilator will
now automatically operate whenever the indoor unit is running.
● To run the ventilator independently:
■ Press the Mode button 2 until
cause the ventilator to start.
● To change the ventilator force:
■ Press the Ventilation button 8 as necessary.
• Each press toggles the setting, as shown below.
Low
High
5.5.2. For Wireless Remote-controller
● The ventilator will automatically operate when the indoor unit turns on.
● No indication on the wireless remote controller.
2. Press the Timer Menu button B, so that the "Set Up" appears on the
screen (at 2). (Note that each press of the button toggles the display
between "Set Up" and "Monitor".)
3. Press the Timer On/Off (Set Day) button 9 to set the day. Each press
advances the display at 3 to the next setting, in the following sequence:
"Sun Mon Tues Wed Thurs Fri Sat" → "Sun" → ... → "Fri" → "Sat" → "Sun
Mon Tues Wed Thurs Fri Sat"...
4. Press the
or
Operation button (7 or 8) as necessary to select the
appropriate operation number (1 to 8) 4.
* Your inputs at Steps 3 and 4 will select one of the cells from the matrix
illustrated below.
(The remote-controller display at left shows how the display would
appear when setting Operation 1 for Sunday to the values indicated
below.)
Setup Matrix
Op No.
Sunday
Monday
• 8:30
No. 1
• ON
• 23 °C
• 10:00
• 10:00
No. 2
• OFF
• OFF
...
No. 8
<Operation 1 settings for Sunday>
<Operation 2 settings for every day>
Start the air conditioner at 8:30, with
Turn off the air conditioner at 10:00.
the temperature set to 23 °C.
Note:
By setting the day to "Sun Mon Tues Wed Thurs Fri Sat", you can set the same
operation to be carried out at the same time every day.
(Example: Operation 2 above, which is the same for all days of the week.)
<Setting the Weekly Timer>
Shows the time
5
6
Shows the selected operation (ON or OFF)
setting
* Does not appear if operation is not set.
SUN
ON
˚C
WEEKLY
5. Press the appropriate Set Time button A as necessary to set the de-
sired time (at 5).
* As you hold the button down, the time first increments in minute inter-
vals, then in ten-minute intervals, and then in one-hour intervals.
6. Press the ON/OFF button 1 to select the desired operation (ON or
OFF), at 6.
* Each press changes the next setting, in the following sequence: No
display (no setting) → "ON" → "OFF"
appears on the display. This will
...
Saturday
• 10:00
• 10:00
• OFF
• OFF
Shows the temperature setting
7
* Does not appear if temperature is not
set.
7