Descargar Imprimir esta página

Parker Hyperchill Plus-E Manual De Uso página 297

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43
,
Variable modbus
MODBUS
unit adress
1
BaudRate
9600
Protocol Parity
1
Address
Display label
App
type
8964
Set
INT
8965
dIF1
INT
8966
dIF2
INT
8969
OFFC
INT
8970
ONC
INT
8973
LiS
INT
8974
HA1
INT
8975
LA1
INT
8976
db1
INT
8977
HA2
INT
8978
LA2
INT
8979
dI2
INT
8980
HA3
INT
8981
LA3
INT
8982
SEA
INT
8983
dIA
INT
8984
ArA
INT
8985
DtHA
INT
8986
SRQH
INT
8987
drq
INT
8988
SrC
INT
8989
drC
INT
8990
SRQL
INT
8995
PStA
INT
8996
ON_OFF_SUP
BOOL
16385
rE
USINT
16387
SUP
BOOL
16384
C-F
BOOL
16386
rAL
USINT
16388
Ud4E
BOOL
16390
ASt
BOOL
16391
r0n
UINT
16465
CPT
BOOL
16445
Erd
BOOL
8999
Dma
INT
8961
dMin
INT
16423
dAS
USINT
16431
tH1
INT
16472
tH1L
INT
16409
CHA1
BOOL
16414
CHA2
BOOL
16411
CLA1
BOOL
16419
rLa
USINT
16420
tLa
USINT
EVEN
Not configurable
NONE
Stop Bit
ODD
Data Bit
Default
Min
Max
Unit
13(55,4)
LIS
65(149)
°C/(°F)
4(7,2)
0,3(0,5)
10(18)
°C/(°F)
0,3(0,5)
0,3(0,5)
10(18)
°C/(°F)
2(3,6)
ONC
10(18)
°C/(°F)
1(1,8)
0(0)
OFFC
°C/(°F)
5(41)
LA2
65(149)
°C/(°F)
60(140)
-40(-40)
65(149)
°C/(°F)
-40(-40)
-40(-40)
65(149)
°C/(°F)
1(1,8)
1(1,8)
10(18)
°C/(°F)
60(140)
-40(-40)
65(149)
°C/(°F)
2,5(36,5)
-40(-40)
65(149)
°C/(°F)
4(7,2)
1(1,8)
10(18)
°C/(°F)
60(140)
-40(-40)
65(149)
°C/(°F)
-30(-22)
-30(-22)
65(149)
°C/(°F)
19(66,2)
LIS
65(149)
°C/(°F)
1(1,8)
1(1,8)
10(18)
°C/(°F)
5(41)
-30(-22)
65(149)
°C/(°F)
5(9)
0(0)
30(54)
°C/(°F)
30(86)
-10(14)
55(131)
°C/(°F)
19(34,2)
0(0)
30(54)
°C/(°F)
15(59)
-30(-22)
50(122)
°C/(°F)
2(36)
0(0)
10(18)
°C/(°F)
5(41)
-10(14)
30(86)
°C/(°F)
0
0
1
FALSE
FALSE
TRUE
0
0
2
FALSE(0)
FALSE(0)
TRUE(1)
FALSE(0)
FALSE(0)
TRUE(1)
0
0
2
FALSE(0)
FALSE(0)
TRUE(1)
TRUE(1)
FALSE(0)
TRUE(1)
6
0
300
sec
FALSE(0)
FALSE(0)
TRUE(1)
FALSE(0)
FALSE(0)
TRUE(1)
25(77)
0(32)
37(98,6)
°C/(°F)
15(59)
-20(-40)
37(98,6)
°C/(°F)
5
0
10
Minutes
0
0
9999
KHours
0
0
9999
Hours
TRUE(1)
FALSE(0)
TRUE(1)
TRUE(1)
FALSE(0)
TRUE(1)
FALSE(0)
FALSE(0)
TRUE(1)
5
0
15
60
5
60
Minutes
Address with offset 40000 (es: 8964+40000=48964)
Read Only
Read&write Set point
Read&write Differential 1 for thermostating
Read&write Differential 2 for thermostating
Read&write Differential for compressor OFF
Read&write Dirrerential for compressor ON
Read&write Set point lower limit
Read&write B1 High terperature alarm
Read&write B1 Low temperature alarm
Read&write B1 Low level temperature alarm retrigger
Read&write B2 High temperature alarm
Read&write B2 Low temperature alarm
Read&write B2 Alarm differential
Read&write B3High temperature alarm
Read&write B3 Low temperature alarm
Read&write Set point (B1) antifreeze
Read&write Thermostating differential (B1)
Read&write Set point activation (B3)
Read&write Differential for dipendent water exit regulation
Read&write SetH point for control panel heater
Read&write Differential control panel heater
Read&write Setpoint Carter Heater
Read&write Differential value for carter heater
Read&write SetL point for control panel resistor
Read Only
Status ON/OFF dryer
Read&write Supervisor ON OFF request (to change the state machine - change True from "0" to "1")
Read&write Remote ON/OFF enable
Read&write ON/OFF enable from supervison
Read&write Unit of measure (FALSE=°C, TRUE=°F)
Read&write Alarm relè management
Read&write Enable antifreeze resistor 0=disabled
Read&write Autostart enable 0=NO 1=YES
Read&write Main power supply return
Read&write CPT control 1=Enable
Read&write Enable managing water with Ambient temperature
Read&write Max value to stop compressor in ERD
Read&write Min value to run compressor in ERD
Read&write Minimun time between two switch ON of the same compressor (minutes)
Read&write Compressor 1 working hours warning threshold (x1000)
Read&write Compressor 1 working hours warning threshold
Read&write HA1 alarm management
Read&write HA2 alarm management 0=Warning; 1=Alarm; 2=System
Read&write LA1 alarm management
Read&write Max number of Events LA2 Alarm
Read&write Interval Time LA2 Alarm
ICEP080E-ICEP120E
Note
13

Publicidad

loading

Este manual también es adecuado para:

Icep 080eIcep 100eIcep 120e