Chrono-thermostat
PARAMETER
UT01
Sets the current day and method of use
UT02
Sets the current time
UT03
Sets minutes
UT04
Sets technical parameters (RESERVED)
UT05
Sets PROGRAM 1 switch-on time
UT06
Sets PROGRAM 1 switch-off time
UT07
Choice of days with stove ignition
UT08
Sets PROGRAM 2 switch-on time
UT09
Sets PROGRAM 2 switch-off time
UT10
Choice of days with stove ignition
UT11
Sets PROGRAM 3 switch-on time
UT12
Sets PROGRAM 3 switch-off time
UT13
Choice of days with stove ignition
UT14
Sets PROGRAM 4 switch-on time
UT15
Sets PROGRAM 4 switch-off time
UT16
Choice of days with stove ignition
The chrono-thermostat function allows to program automatic switch-on/off of the thermo stove throughout the week.
Press button 3 twice to enter programming. Press button 3 again to scroll all of the programming parameters explained below. Pressing key 4 allows to exit
programming ay any time.
Find all of the parameters in detail below:
UT01
The parameter allows to set the current day of the week, select functioning day by day (weekly mode) or disconnect programming.
Lun
Mar
Mer
Gio
Ven
Sab
Dom
OFF
It is possible to set 4 time intervals when to switch the thermo stove on during the day. If the UT01 parameter is set with the current day (for example
Tuesday/Tue) it is possible to associate the ignition of PROGRAM 1, 2, 3 and 4. By pressing buttons 1 and 2 the desired value can be selected. This can be
carried out for every day of the week, as there is the possibility to select on which days to ignite the thermo stove and on which days to leave it off.
UT02
The parameter allows to set the current time. The time is shown in the lower display.
UT03
Used to set the minutes.
UT04
Reserved technical parameter. Only for After-sales centres.
UT05-UT06
Parameters to respectively set the switch-on and switch-off time of PROGRAM 1. Their setting is active whenever the UT01 parameter is set in weekly
mode.
UT07
This parameter is active and assumes meaning when the UT01 parameter is set in weekly mode. When PROGRAM 1 programming is active, use button 1 to
select the day of the week and use button 2 to activate/deactivate ignition of the insert. The example that follows shows ignition of the insert takes place only
on Saturday and Sunday.
Lun
Mar
Monday
Tuesday
Lun/off
Mar/off
UT08 - UT09
Parameters to respectively set the switch-on and switch-off time of PROGRAM 2. Their setting is active whenever the UT01 parameter is set in weekly
mode.
UT10
This parameter is active and assumes meaning when the UT01 parameter is set in weekly mode. When PROGRAM 2 programming is active, use button 1 to
select the day of the week and use button 2 to activate/deactivate ignition of the insert. The example that follows shows ignition of the insert takes place only
on weekdays.
Lun
Mar
Monday
Tuesday
Lun/on
Mar/on
UT11 - UT12
Parameters to respectively set the switch-on and switch-off time of PROGRAM 3. Their setting is active whenever the UT01 parameter is set in weekly
mode.
DESCRIPTION
Upper display
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Chrono-thermostat off
Mer
Gio
Wednesday
Thursday
Mer/off
Gio/off
Mer
Gio
Wednesday
Thursday
Mer/on
Gio/on
13
VALUE THAT CAN BE SET
OFF, Lun, Mar, Mer, ..., Dom
From 00 to 23
From 00 to 59
From 00 to P5
From 00:00 to 23:50 in 10' steps
From 00:00 to 23:50 in 10' steps
Between on/off from Mon to Sun
From 00:00 to 23:50 in 10' steps
From 00:00 to 23:50 in 10' steps
Between on/off from Mon to Sun
From 00:00 to 23:50 in 10' steps
From 00:00 to 23:50 in 10' steps
Between on/off from Mon to Sun
From 00:00 to 23:50 in 10' steps
From 00:00 to 23:50 in 10' steps
Between on/off from Mon to Sun
Meaning
Ven
Sab
Friday
Saturday
Ven/off
Sab/on
Ven
Sab
Friday
Saturday
Ven/on
Sab/off
Dom
Sunday
Dom/on
Dom
Sunday
Dom/off